SERVICE (cont.)
LIMIT THERMOSTAT
P1586 |
FIG. 4 LIMIT THERMOSTAT |
Location:
The limit thermostat is located on the rear of tank assembly.
Test Procedures:
1.Disconnect the brewer from the power source.
2.Disconnect the blue and black wires from the limit thermostat.
3.Check for continuity across the limit thermostat terminals with a ohmmeter.
If continuity is present as described, the limit thermo- stat is operating properly. If continuity is not present as described, replace the limit thermostat.
Removal and Replacement:
1.Remove all wires from limit thermostat termi- nals.
2.Carefully slide the limit thermostat out from under the retaining clip and remove limit thermo- stat.
3.Carefully slide the new limit thermostat into the retaining clip.
4.Refer to FIG. 5 when reconnecting the wires.
BLK to Tank |
|
|
|
| BLK to BLU Lead from |
Heater Switch |
|
|
| Control Thermostat | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
P1800
FIG. 5 LIMIT THERMOSTAT TERMINALS
Page 16 | 29251 052500 |
|