LIQUID LEVEL CONTROL BOARD (Models STF & STFA)

SERVICE (cont.)

LIQUID LEVEL CONTROL BOARD (Models STF & STFA)

P1598

FIG. 18 LIQUID LEVEL PROBE

& CONTROL BOARD

Location:

The liquid level probe is located within the tank lid inside the fill basin. The liquid level board is located inside the rear inspection panel on the top left of component mounting bracket.

Test Procedure.

1.Disconnect the brewer from the power source.

2.Remove the blue wire from terminal 1 and the pink wire from terminal 4 of the circuit board.

3.Check the voltage across terminals 2 and 3 with a voltmeter. Connect the brewer to the power source. Turn the "ON/OFF" switch to the "ON" position.The indication must be:

a)120 volts ac for two wire 120 volt models and three wire 120/240 volt models.

b)200 to 240 volts ac for two wire 200 volt or 240 volt models.

c)100 volts ac for two wire 100 volt models.

4.Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the wiring diagrams and check the brewer wiring harness.

5.Reconnect the blue wire to terminal 1.

6.Carefully connect a piece of insulated jumper wire to terminal 4. Keep the other end of this wire away from any metal surface of the brewer.

7.Check the voltage across terminals 1 & 3 with a voltmeter. Connect the brewer to the power source.Turn the "ON/OFF" switch to the "ON" position The indication must be:

a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models after a delay of approximately 5 seconds.

b.) 200 to 240 volts ac for two wire 200 or 240 volt models after a delay of approximately 5 seconds.

8.Touch the free end of jumper wire to the brewer housing. The indication must be 0.

9.Move the jumper wire away from the brewer housing. The indication must again be:

a.) 120 volts ac for three wire 120/208 volt models and three wire 120/240 volt models after a delay of approximately 5 seconds.

b.) 200 to 240 volts ac for two wire 200 or 240volt models after a delay of approximately 5 seonds.

10.Disconnect the brewer from the power source and remove the jumper wire from terminal 4.

Page 26

29251 052500

 

Page 26
Image 26
Bunn STA, SA service manual LIQUID LEVEL CONTROL BOARD Models STF & STFA, SERVICE cont