TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Consistently high or low beverage | 2. External Strainer/Flow Control | (A) Direction of flow arrow must be |
level in the dispenser. (cont.) | (.750 GPM) | pointing towards brewer. |
|
| (B) Remove the strainer/flow con- |
|
| trol and check for obstructions. |
|
| Clear or replace. |
Spitting or excessive steaming | 1. Lime |
| CAUTION - Tank and tank compo- |
| nents should be delimed regularly |
| depending on local water condi- |
| tions. Excessive mineral |
| on stainless steel surfaces can ini- |
| tiate corrosive reactions resulting |
| in serious leaks. |
Inspect tank assembly for excessive lime deposits. Delime as required.
| 2. | Control Thermostat | Refer to Service - Control Thermo- |
|
|
| stat for testing procedures. See |
|
|
| page 23 |
1. | Funnel Tip | The brew funnel should be cleaned | |
|
|
| thoroughly before each brew cycle |
|
|
| to lessen the chance of tea leaf par- |
|
|
| ticles clogging the |
Dripping from sprayhead | 1. | Syphon System |
| 2. | Lime |
CAUTION - Tank and tank compo- nents should be delimed regularly depending on local water condi- tions. Excessive mineral
The brewer must be level or slightly lower in front to syphon properly.
Inspect the tank assembly for ex- cessive lime deposits. Delime as required.
3. Brew Solenoid Valve | Refer to Service - Brew Solenoid |
A) Iced Tea | Valve (Iced Tea) for testing proce- |
| dures. See page 16 |
B) Hot Coffee | Refer to Service- Brew Solenoid |
| Valve (Hot Coffee) for testing pro- |
| cedures. See Page 15 |
Page 11 | 10510 | 071000 |
|
|