TROUBLESHOOTING (cont.) |
|
|
PROBLEM | PROBABLE CAUSE | REMEDY |
Brew cycle(s) will not start (cont.) | 6. Brew Timer | Refer to Service - Brew Timer (Iced |
| A) Iced Tea | |
|
| Tea) for testing procedures. See |
|
| page 20 or 21 |
| B) Hot Coffee | Refer to Service - Brew Timer (Hot |
|
| Coffee) for testing procedures. See |
|
| page 17 or 18 |
| 7. Brew Solenoid Valve | Refer to Service - Brew Solenoid |
| A) Iced Tea | Valve (Iced Tea) for testing proce- |
|
| dures. See page 16 |
| B) Hot Coffee | Refer to Service- Brew Solenoid |
|
| Valve (Hot Coffee) for testing pro- |
|
| cedures. See page 15 |
8.Internal Flow control (.195 GPM) (Hot Coffee Only)
(A)Direction of flow arrow must be pointing towards brewer.
(B)Remove the flow control and check for obstructions. Clear or re- place.
Brew water is not hot | 1. Limit Thermostat |
| Refer to Service - Limit Thermostat | |
| CAUTION - Do not eliminate or by- | for testing procedures. See page 25 | ||
| pass limit thermostat. Use only |
| ||
| BOM | replacement | part |
|
#29329.1000
2. Thermal Fuse
CAUTION - Do not eliminate or by- pass thermal fuse.
3. Control Thermostat
Refer to Service - Thermal fuse for testing procedures. See page 29
Refer to Service - Control Thermo- stat for testing procedures. See page 23
| 4. | Tank Heater | Refer to Service - Tank Heater for |
|
|
| testing procedures. See page 28 |
Dilution (Iced Tea) cycle will not | 1. | TEA/OFF/COFFEE Switch | Refer to Service - TEA/OFF/COFFEE |
start |
|
| Switch for testing procedures. See |
|
|
| page 26 |
Page 9 | 10510 | 071000 |
|
|