INITIAL SET-UP (cont.)

ADJUSTING BREW VOLUMES

CAUTION - Disconnect the power source from the brewer prior to the removal of any panel for the replacement or adjustment of any component.

NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply, the tank is properly filled, and a funnel and server are in place.

1.Modifying batch sizes. To modify a batch volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board.

To increase a batch size. Press and hold the START or BREW switch until three clicks are heard. Release the switch (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory) and press it again one or more times. Each time the switch is pressed, two seconds are added to the brew time period. Allow the brew cycle to finish in order to verify that the desired volume has been achieved.

To decrease a batch size. Press and release the START or BREW switch once for every two-second interval to be removed from the total brew time period; then immediately press and hold down the START or BREW switch until three clicks are heard. Release the switch. (Failure to release the switch within two seconds after the third click causes the volume setting to be aborted and previous volume setting will remain in memory). Allow the brew cycle to finish in order to verify that the desired volume has been achieved.

2.Setting batch sizes. To set a batch volume, first check that the SET/LOCK switch is in the “SET” position on the circuit board. Press and hold the START or BREW switch until three distinct clicks are heard, and then release the switch. (Failure to release the switch within two seconds after the third click causes the volume

setting to be aborted and previous volume setting will remain in memory). View the level of the liquid being dispensed. When the desired level is reached, turn the ON/OFF switch to “OFF” (lower). The brewer remem- bers this volume and will continue to brew batches of this size until the volume setting procedure is repeated.

NOTE: When brewing coffee, batch volumes will decrease due to absorption by the coffee grounds.

3.Setting programming disable feature. If it becomes necessary to prevent anyone from changing brew times once programmed, you can set the SET/LOCK switch to the “LOCK” position. This will prevent any program- ming to be done until switch is once again placed in the “SET” position.

CLEANING

CAUTION – Do not keep brewed tea overnight. Clean and sanitize your iced tea dispenser daily

1.Remove and thoroughly clean the brew funnel. The funnel tip and screen must be free from any tea particles or residue. Reassemble the funnel.

2.Unplug the brewer. Remove and thoroughly rinse the sprayhead. The holes must be open and clear of any mineral deposits. Wipe the sprayhead panel clean with a damp cloth.

3.Insert the deliming spring into the sprayhead fitting until no more than one inch is visible and move it in and out 5 or 6 times. Insert the spring into the airvent hole in the sprayhead panel and move it in and out 5 or 6 times. Reattach the sprayhead.

4.Wash the entire outside surface of the brewer with a clean damp cloth.

Page 6

10510

071000

 

 

Page 6
Image 6
Bunn TWF service manual Adjusting Brew Volumes, Cleaning

TWF specifications

The Bunn TWF series is a versatile and high-performance coffee brewing system designed to meet the demanding needs of commercial coffee establishments. Renowned for its reliability and consistency, the Bunn TWF is engineered for high volume production while maintaining exceptional quality in every cup.

One of the main features of the Bunn TWF is its dual-voltage capability, which makes it adaptable to various electrical systems, ensuring that businesses can use it in different locations with ease. It is compatible with both 120V and 220V outlets, providing flexibility for commercial environments.

The TWF employs Bunn's innovative brewing technology, which includes a patented digital pulse brew feature. This system optimizes the extraction process by controlling the flow rate and brewing time, enhancing the flavor profile of the coffee and ensuring that each batch is rich and full-bodied. The ThermoFresh technology allows for excellent thermal retention, ensuring that the coffee remains hot and fresh for extended periods without a heated plate that can alter the taste.

Another significant characteristic of the Bunn TWF is its brewing capacity. The machine can brew up to 16.3 gallons of coffee per hour, making it an ideal choice for busy cafes, restaurants, and catering services. The large capacity also translates to less downtime, enabling staff to serve customers more efficiently.

The Bunn TWF is equipped with a user-friendly control interface, featuring intuitive buttons and an easy-to-read display. This allows for precise programming and brewing options, accommodating various coffee types and recipes. Users can easily set up their preferred brewing parameters, making it convenient to replicate the same great taste repeatedly.

Moreover, the design of the Bunn TWF emphasizes durability and ease of maintenance. Constructed from high-quality materials, it can withstand the rigors of daily use in a bustling coffee shop environment. The machine is also designed for easy cleaning, with removable components that simplify upkeep and prolong its lifespan.

In conclusion, the Bunn TWF is an exceptional choice for those in the coffee business looking to elevate their brewing game. With its outstanding features, advanced technologies, and user-focused design, it stands out as a leader in commercial coffee brewing solutions. Whether for a high-traffic café or a catering operation, the Bunn TWF is engineered to deliver quality and efficiency while satisfying the most discerning coffee connoisseurs.