TROUBLESHOOTING (cont.) |
|
PROBLEM | PROBABLE CAUSE |
REMEDY
Water flows into tank continuously (TEA/OFF/COFFEE Switch in the "TEA or "COFFEE" position)
Water flows into tank continuously (TEA/OFF/COFFEE Switch in the "OFF" position)
Beverage overflows dispenser
1.Brew Timer
A)Iced Tea
B)Hot Coffee
1.Brew Solenoid Valve
A)Iced Tea
B)Hot Coffee
1.Dispenser
2.Brew Timer
A)Iced Tea
Refer to Service - Brew Timer (Iced Tea) for testing procedures. See page 20 or 21
Refer to Service- Brew Timer (Hot Coffee) for testing procedures. See page 17 or 18
Refer to Service - Brew Solenoid Valve (Iced Tea) for testing proce- dures. See page 16
Refer to Service- Brew Solenoid Valve (Hot Coffee) for testing pro- cedures. See page 15
The dispenser must be completely empty before starting a brew cycle.
Refer to Service - Brew Timer (Iced Tea) for testing procedures. See page 20 or 21
B)Hot Coffee
3.Brew Solenoid Valve
A)Iced Tea
B)Hot Coffee
4.Dilution Solenoid Valve
Refer to Service- Brew Timer (Hot Coffee) for testing procedures. See page 17 or 18
Remove the Iced Tea Brew Solenoid Valve and clean any obstruction. Rebuild or replace the valve if nec- essary. See page 16
Remove the Hot Coffee Brew Sole- noid Valve and clean any obstruc- tion. Rebuild or replace the valve if necessary. See page 15
Refer to Service - Dilution Solenoid Valve for testing procedures. See page 24
Page 12 | 10510 | 071000 |
|
|