Bunn TWF service manual SERVICE cont, Brew Solenoid Valve Hot Coffee, solenoid valve

Models: TWF

1 32
Download 32 pages 47.14 Kb
Page 15
Image 15
SERVICE (cont.)

SERVICE (cont.)

If continuity is not present as described, replace the

BREW SOLENOID VALVE (HOT COFFEE)

solenoid valve.

 

 

6.

Check the hot coffee solenoid valve for coil ac-

 

 

 

tion. Connect the brewer to the power source. With

 

 

 

TEA/OFF/COFFEE switch in the "COFFEE" position

 

 

 

press the START switch and listen carefully in the

 

 

 

vicinity of the solenoid valve for a "clicking" sound

 

 

 

as the coil magnet attracts.

 

 

7.

Disconnect the brewer from the power source.

 

 

If the sound is heard as described and water will not

 

 

pass through the solenoid valve, there may be a block-

 

 

age in the water line before the solenoid valve or, the

 

 

solenoid valve may require inspection for wear, and

 

 

removal of waterborne particles.

 

 

If the sound is not heard as described, replace the

 

 

solenoid valve.

 

P2198.50

Removal and Replacement:

 

FIG. 2 HOT COFFEE BREW SOLENOID VALVE

1.

Remove all wires from solenoid valves.

Location:

2.

Turn off the water supply to the brewer.

 

Viewing the brewer from the, rear the hot coffee

3.

Disconnect the water lines to and from the sole-

brew solenoid valve is mounted on the left side of the

 

noid valves.

mounting bracket.

4.

Remove the two #8-32 keps nuts holding the

 

 

 

mounting bracket to the brewer base.

Test Procedures:

5.

Lift out the bracket.

1. Disconnect the brewer from the power source.

6.

Remove the two #10-32 slotted-head screws hold-

2. Disconnect the white/red and white/green wires

 

ing the hot coffee solenoid valve to the mounting

 

from the hot coffee solenoid valve. With the TEA/

 

bracket.

 

OFF/COFFEE switch in the "COFFEE" position press

7.

Securely install the new hot coffee solenoid valve

 

the START switch.

 

to the mounting bracket.

3.

With a voltmeter, check the voltage across the

8.

Attach the mounting bracket to the brewer base.

 

white/red and white/green wires. Connect the

9.

Securely fasten the water lines to and from the

 

brewer to the power source. The indication must

 

solenoid valves.

 

be 120 volts ac for two wire 120 volt models and

10.

Refer to Fig. 3 when reconnecting the wires.

 

three wire 120/208 volt models.

 

WHI/GRN to Hot Coffee Timer TL4

4.

Disconnect the brewer from the power source.

 

WHI/RED to Hot Coffee Timer TL1

If voltage is present as described, proceed to #5

If voltage is not present as described, refer to Wiring

Diagrams and check brewer wiring harness.

5. Check for continuity across the hot coffee sole-

HOT COFFEE

 

 

noid valve coil terminals.

BREW SOLENOID

 

 

ICED TEA BREW

 

 

 

 

 

If continuity is present as described, reconnect the

SOLENOID

 

 

 

DILUTION

 

white/red and white/green wires from the hot coffee

 

 

 

SOLENOID

P1364

brew timer.

FIG.3 SOLENOID VALVE TERMINALS

 

Page 15

10510

081599

 

 

Page 15
Image 15
Bunn TWF service manual SERVICE cont, Brew Solenoid Valve Hot Coffee, solenoid valve