SERVICE (cont.) | If continuity is not present as described, replace the | ||
BREW SOLENOID VALVE (ICED TEA) | solenoid valve. | ||
|
| ||
|
| 6. | Check the iced tea solenoid valve for coil action. |
|
|
| Connect the brewer to the power source. With TEA/ |
|
|
| OFF/COFFEE switch in the "TEA" position press |
|
|
| the START switch and listen carefully in the vicin- |
|
|
| ity of the solenoid valve for a "clicking" sound as |
|
|
| the coil magnet attracts. |
|
| 7. | Disconnect the brewer from the power source. |
|
| If the sound is heard as described and water will not | |
|
| pass through the solenoid valve, there may be a block- | |
|
| age in the water line before the solenoid valve or, the | |
|
| solenoid valve may require inspection for wear, and | |
|
| removal of waterborne particles. | |
|
| If the sound is not heard as described, replace the | |
|
| solenoid valve. | |
| P2198.50 | Removal and Replacement: | |
|
|
| |
| FIG. 4 ICED TEA BREW SOLENOID VALVE | 1. | Remove all wires from solenoid valves. |
Location: | 2. | Turn off the water supply to the brewer. | |
| Viewing the brewer from the rear, the iced tea brew | 3. | Disconnect the water lines to and from the sole- |
solenoid valve is mounted in the center of the mount- |
| noid valves. | |
ing bracket. | 4. | Remove the two | |
|
|
| mounting bracket to the brewer base. |
Test Procedures: | 5. | Lift out the bracket. | |
1. Disconnect the brewer from the power source. | 6. | Remove the two | |
2. Disconnect the white/violet and white/blue wires |
| ing the iced tea brew solenoid valve to the mount- | |
| from the iced tea brew solenoid valve. With the |
| ing bracket. |
| TEA/OFF/COFFEE switch in the "TEA" position press | 7. | Securely install the new iced tea brew solenoid |
| the START switch. |
| valve to the mounting bracket. |
3. | With a voltmeter, check the voltage across the | 8. | Attach the mounting bracket to the brewer base. |
| white/violet and white/blue wires. Connect the | 9. | Securely fasten the water lines to and from the |
| brewer to the power source. The indication must |
| solenoid valves. |
| be 120 volts ac for two wire 120 volt models and | 10. | Refer to Fig. 5 when reconnecting the wires. |
| three wire 120/208 volt models. |
|
|
4. Disconnect the brewer from the power source. |
|
|
If voltage is present as described, proceed to #5 | WHI/BLU to Dilution | |
Solenoid | ||
If voltage is not present as described, refer to Wiring | WHI/VIO to Dilution | |
Diagrams and check brewer wiring harness. | Solenoid | |
| ||
5. Check for continuity across the iced tea brew so- | HOT COFFEE | |
lenoid valve coil terminals. | BREW SOLENOID | |
ICED TEA BREW | ||
| ||
| SOLENOID | |
If continuity is present as described, reconnect the | DILUTION | |
white/violet and white/blue wires from the iced tea | ||
SOLENOID | ||
brew timer. | FIG.5 SOLENOID VALVE TERMINALS P1364 | |