Honeywell EI Ignition Module Yellow LED Flame Codes

Yellow LED

Indicates

Recommended Service Action

Flash Codea

 

 

 

Heartbeat

Normal Flame Signal

N/A

 

 

 

 

Weak Flame Signal -

 

 

System will operate reliably but flame signal is less than

Perform routine maintenance to

2

desired.

assure optimum flame signal.

 

Note: This indication may flash temporarily during or

 

 

 

shortly after lightoff on some applications.

 

 

 

 

 

Marginal Flame Signal (less than 1.1 µA) -

 

 

System may not operate reliably over time. Service call

Check gas supply, pilot burner, flame

1

recommended.

sense wiring, contamination of flame rod,

 

Note: This indication may flash temporarily during or

burner ground connection.

 

shortly after lightoff on some applications.

 

OFF

No Flame or Flame Signal -

N/A

below minimum threshold for system operation.

 

 

 

 

 

aFlash Code Descriptions

 

-Heartbeat: Constant ½ second bright, ½ second dim cycles.

-The flash code number signifies that the LED flashes X times at 2Hz, remains off for two seconds, and then repeats sequence.