Cabletron Systems 9033073 manual ELECTRICAL HAZARD WARNINGS Continued, Installing the Antenna

Models: 9033073

1 80
Download 80 pages 18.07 Kb
Page 47
Image 47
ELECTRICAL HAZARD WARNINGS (Continued)

Installing the Antenna

Planning the Antenna Installation

ELECTRICAL HAZARD WARNINGS (Continued)

6. The low-loss antenna cable that connects the antenna to the lightning protector must be at least 1m (3 ft) away from any high voltage or high current cable.

7.Check whether the antenna mast and its guy wires or wall bracket are positioned correctly and secured properly to the roof or wall(s).

8.Check whether the grounding system for the antenna mast, the RoamAbout Access Point, and RoamAbout Lightning Protector have been installed. The grounding system must comply with the requirements as described in Chapter 2, Grounding System on page 2-15.

9.Always consult a qualified electrician if you are in doubt as to whether the antenna mast, Lightning Protector, and/or RoamAbout Access Point is properly grounded.

10.The low-loss antenna cable between the antenna and the lightning arrestor must be grounded at all times. If the cable is disconnected at one end for some reason (for example, to replace the lightning arrestor), you must locally ground the exposed metal connector of the cable during the work.

11.Install the Danger label shipped with the antenna on a plainly visible area of the antenna support structure.