INSTALLATION REQUIREMENTS/SPECIFICATIONS
Page 2-13
Parameter Typical Minimum Maximum
Transmitter Peak
Wave Length 1300 nm 1270 nm 1330 nm
Spectral Width 60 nm - 100 nm
Rise Time/ 3.0 nsec 2.7 nsec 5.0 nsec
Fall Time 2.5 nsec 2.2 nsec 5.0 nsec
Duty Cycle 50.1% 49.6% 50.7%
Bit Error Rate: Better than 10-10
Note: The transmitter power levels given above are Peak Power
Levels after optical overshoot. You must use a Peak Power Meter to
correctly compare the values given above to those measured on any
particular port. If you are measuring power levels with an Average
Power Meter, add 3 dBm to the average power measurement to
correctly compare the average power values measured to the values
listed above (i.e. -33.5 dBm average + 3 dB = -30.5 dBm peak).
Receive
Sensitivity
dBm
Less Power More Power
-40 -35 -30 -25 -20 -15 -10 -5 0
Maximum
Receive
Input Power
Transmitter Power*
(At 25°C into
8.3/125µm fiber)
Minimum Sensitivity (-30.0)
Typical Sensitivity (-31.0)
Maximum Sensitivity (-36.0)
Maximum Receive Input (-6.99)
Typical Receive Input (-7.5)
Minimum Receive Input (-9.72)
Maximum Transmit Power (-12.0)
Typical Transmit Power (-15.5)
Minimum Transmit Power (-21.0)
* Transmit Power Typical Power Minimum Power Maximum Power
Coefficient
(See Note Below)-0.15dBm/ °C  -0.12 dBm/ °C-0.18 dBm/ °
C