INSTALLATION REQUIREMENTS/SPECIFICATIONS

JAM Output:

Collisions are propagated

 

through the network using the

 

JAM signal of an alternating

 

pattern of 1's and 0's in

 

accordance with 802.3

 

specifications for a repeater unit.

Fragment Extension:

Packet fragments are extended to

 

a minimum of 96 bits using the

 

JAM [1,0].

Fault Protection:

Each segment will disconnect

 

itself from the other segments if

 

32 consecutive collisions occur, or

 

if the collision detector of a

 

segment is on for longer than

 

approximately 110 ∝s. This fault

 

protection will reset

 

automatically after one packet is

 

transmitted/received onto the

 

fault protected segment without

 

causing a collision.

POWER SUPPLY REQUIREMENTS

Note: The SEH has a universal power supply. This unit allows you to use an input power from 90 to 264 VAC, 47-63 Hz.

The power supply has two outputs of +5 volts and +12 volts. The maximum output power is 20 watts and the minimum efficiency is 65% under all conditions of line at full load. The minimum and maximum load current from each output is shown below.

Output

Min. Load

Max. Load

Max Power

+5 Volts

0.50 Amps

3.0 Amps

15 Watts

+12 Volts

0.05 Amps

1.0 Amps

12 Watts