CONNECTING TO THE NETWORK

To connect twisted pair segments to the SEH:

1.Insert the RJ45 connector from each twisted pair segment into the desired network port on the SEH. See Figure 4-1.

18X

6X

17X

5X

16X

4X

15X

3X

14X

2X

13X

1X

EPIM-2

LNK

EPIM-T

LNK

EPIM-T

EPIM-1

Figure 4-1. SEH-22/24 Network Ports

2.Check that the applicable LNK LED for the port is on. If the LED is not on, perform each of the following steps until it is:

a.Check that the 10BASE-T device at the other end of the twisted pair segment is powered up.

b.Verify that the RJ45 connector on the twisted pair segment has the proper pinouts. Check the cable for continuity.

c.Check that the twisted pair connection meets dB loss and cable specifications outlined Chapter 2.

If a link still has not been established, contact Cabletron Systems Technical Support.