Fast Ethernet

Port Count

The first device in the stack, whether an intelligent SEHI100TX-22 or non-intelligent SEH100TX-22, will provide connections for up to 22 Fast Ethernet stations. For every additional 22 Fast Ethernet stations or fraction thereof, the Network Designer must add one SEH100TX-22 to the stack.

The maximum number of ports that can be supported in this fashion is 110. In order to support more connections, the user-configurable EPIM slots on the SEHI100TX-22 and SEH100TX-22 will have to be used. If the EPIM slots are all used, the Fast Ethernet stack will reach its limitation of 119 users. Any Fast Ethernet workgroup containing more than 119 stations will require the creation of another workgroup to support the full user count.

Design Example

A travel agency sales department is looking to replace its current Ethernet network with a Fast Ethernet network in order to gain higher throughput and faster access to shared resources such as the two departmental file servers and the order entry system. The department also plans to add twenty sales representatives to the current network in the coming fiscal quarter.

Order Entry

Servers (2)

repeater

repeater

Stations (40)

2094n21

Figure 7-1. Small Office Network - Current Status

7-4

Fast Ethernet Workgroup Design

Page 90
Image 90
Cabletron Systems switches, bridges manual Order Entry Servers Repeater Stations