Operating Your Spa

Ozone

This is an optional feature. On most systems, the ozone generator (if installed) runs during filter cycles (except when pump 1 is operating at high speed on a non-circ system) and during clean-up cycles. On some systems, the ozone generator operates whenever the pump runs. If your system is configured with the optional ozone disable feature, the ozone generator will turn off for one hour any time a function button (JETS 1, JETS 2, OPTION etc.) is pressed.

Freeze Protection

If the temperature sensors detect a drop to 44°F within the heater, the pump automatically activates to provide freeze protection. The equipment stays on until four minutes after the sensors detect that the spa temperature has risen to 45°F or higher. In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch and without a four minute delay in turnoff.

Periodic Reminder Messages

Press the “Mode” button to reset a displayed reminder.

Message

Frequency

Action Required

 

 

 

rPH

Every 7 days

Test and adjust chemical levels per manufacturer’s

 

 

instructions.

rSA

Every 7 days

Test and adjust chemical levels per manufacturer’s

 

 

instructions.

 

 

 

rCL

Every 30 days

Remove, clean, and reinstall filter per

 

 

manufacturer’s instructions.

rtg

Every 30 days

Test and reset GFCI per manufacturer’s instructions.

 

 

Drain and refill spa per manufacturer’s instructions.

 

 

 

rdr

Every 90 days

Drain and refill spa per manufacturer’s instructions.

 

 

 

rCO

Every 180 days

Clean and condition spa cover

 

 

 

rCH

Every 365 days

Install New Bio-Clean™ Filter

 

 

 

WARNING! SHOCK HAZARD!

There are no user serviceable parts. DO NOT attempt service of this control system. Contact your dealer

or service center for service.

Diagnostic Messages

Message

Meaning

Action Required

 

No message on display. Power has

The control panel will be disabled until power

 

been cut off to the spa.

returns. Spa settings and time of day will be

 

 

preserved for 30 days with a battery back-up;

 

 

settings only are preserved until the next power-up

 

 

on 9800 systems.

Page 28

2005 Spa Owner's Manual

 

8/1/2005