| Operating Your Spa |
|
|
|
|
|
|
| Message | Meaning | Action Required |
|
| ICE | “Ice” - Potential freeze condition | No action required. The pumps and the blower will |
|
|
| detected. | automatically activate regardless of spa status. |
|
| Sna | Spa is shut down. The sensor that is | If the problem persists, contact your dealer or service |
|
|
| plugged into the Sensor “B” jack is | organization. (May appear temporarily in an overheat |
|
|
| not working. | situation and disappear when the heater cools.) |
|
| Snb | Spa is shut down. The sensor that is | If the problem persists, contact your dealer or service |
|
|
| plugged into the Sensor “A” jack is | organization. (May appear temporarily in an overheat |
|
|
| not working. | situation and disappear when the heater cools.) |
|
| Sns | Sensors are out of balance. If this is | If the problem persists, contact your dealer or service |
|
|
| alternating with the temperature, it | organization. |
|
|
| may just be a temporary condition. If |
|
|
|
| the display shows only this message |
|
|
|
| (periodically blinking), the spa is shut |
|
|
|
| down. |
|
|
| HFL | A substantial difference between the | If the water level is okay, make sure the pumps have |
|
|
| temperature sensors was detected. | been primed. If problem persists, contact your dealer |
|
|
| This could indicate a flow problem. | or service organization. |
|
| LF | Persistent low flow problems. | Follow action required for “HFL” message. Heating |
|
|
| (Displays on the fifth occurrence of | capacity of the spa will not reset automatically; you |
|
|
| the “HFL” message within 24 hours.) | may press any button to reset. |
|
|
| Heater is shut down, but other spa |
|
|
|
| functions continue to run normally. |
|
|
| dr | Inadequate water detected in heater. | Check water level in spa. Refill if necessary. If the |
|
|
|
| water level is okay, make sure the pumps have been |
|
|
|
| primed. Press any button to reset. |
|
| dry | Inadequate water detected in heater. | Follow action required for “dr” message. Spa will not |
|
|
| (Displays on third occurrence of “dr” | automatically reset; you may press any button to |
|
|
| message.) Spa is shut down. | reset. |
|
| Pr | When your spa is first actuated, it | The Priming mode will last for up to four minutes and |
|
|
| will go into Priming mode. | then the spa will begin to heat and maintain the water |
|
|
|
| temperature in the Standard mode. |
|
| Temperature unknown | After the pump has been running for two minutes, the |
| |
|
|
| temperature will be displayed. |
|
| - - - - - - | Temperature not current in Economy | In Economy or Sleep mode, the pump may be off for |
|
|
| or Sleep mode. | hours outside a filter. If you wish to see the current |
|
|
|
| spa temperature, either switch to Standard mode or |
|
|
|
| turn Jets1 on for at least two minutes. |
|
| BUF | Internal problem detected. | Repair required. Contact your dealer or service |
|
|
|
| organization. |
|
| Stby | Standby Mode has been activated by | Press any button to leave Standby Mode and return to |
|
|
| pressing a button combination on the | normal operation. |
|
|
| user panel. |
|
|
| SF | Safety Suction. | Spa is shut down. The display will show “SF” when |
|
|
|
| a vacuum switch closes. All functions will turn off |
|
|
|
| and the system will be disabled until a panel button is |
|
|
|
| pressed. |
|
|
|
|
|
|
| 2005 Spa Owner's Manual | Page 35 |
| |
| 8/1/2005 |
|
|
|