9800 Configuration Settings
WARNING! SHOCK HAZARD!
There are no user serviceable parts. DO NOT attempt service of this control system. Contact your dealer or service center for service.
DIP Switches and Jumpers
Note: Switchbank B is totally disabled.
|
| A1 | Test mode OFF | A7 | N/A |
|
| A2 | Add 1 pump with heat | A8 | N/A |
|
| A3 | Add 2 pumps with heat | A9 | N/A |
|
| A4 | N/A | A10 | No edit |
|
| A5 | N/A | A11 | N/A |
|
| A6 | N/A | A12 | Memory ON |
|
| A1 | Test mode OFF | A7 | N/A |
|
| A2 | Add 1 pump with heat | A8 | N/A |
|
| A3 | Add 2 pumps with heat | A9 | N/A |
|
| A4 | Add 3 pumps with heat | A10 | No edit |
|
| A5 | N/A | A11 | N/A |
|
| A6 | N/A | A12 | Memory ON |
|
| A1 | Test mode OFF | A7 | N/A |
|
| A2 | Add 1 pump with heat | A8 | N/A |
|
| A3 | Add 2 pumps with heat | A9 | N/A |
|
| A4 | N/A | A10 | No edit |
|
| A5 | N/A | A11 | N/A |
|
| A6 | N/A | A12 | Memory ON |
DIP Switch Key |
|
|
|
| |
A1 | Test mode (normally off) |
|
|
| |
A2 | In ON mode, add one |
|
| ||
A3 | In ON mode, add two | ||||
A4 | In ON mode, add four | ||||
N/A |
|
|
| ||
A10 | When switched on when spa is on, system will enter the Edit Menu for configuration settings. Do | ||||
| not start the spa with A10 turned on or a CFE error will occur. (CFE errors are illegal configurations | ||||
| such as a pump and blower set to run on the same output. The configuration must be corrected | ||||
| before the spa will operate. |
|
|
| |
A11 | N/A |
|
|
| |
A12 | Persistent memory reset (used when spaq is powering up) |
|
| ||
Note: A2, A3, and A4 work in combination. Example: A2 and A3 in the ON position and A4 in the OFF position will allow 3 high speed pumps (or two high speed pumps and the blower) to run with the heater.