Operating SpaYour
Periodic Reminder Messages
Press the “Mode” button to reset a displayed reminder.
Message | Frequency | Action Required | |
rPH | Every 7 days | Test and adjust chemical levels per manufacturer’s instructions. | |
|
|
|
|
rSA | Every 7 days | Test and adjust chemical levels per manufacturer’s instructions. | |
|
|
|
|
rCL | Every 30 days | Remove, clean, and reinstall filter per manufacturer’s instructions. | |
|
|
|
|
rtg | Every 30 days | Test and reset GFCI per manufacturer’s instructions. Drain and refill | |
|
| spa per manufacturer’s instructions. | |
|
|
|
|
rdr | Every 90 days | Drain and refill spa per manufacturer’s instructions. | |
|
|
|
|
rCO | Every 180 days | Clean and condition spa cover. | |
|
|
|
|
rCH | Every 365 days | Install a new filter. | |
|
|
|
|
Diagnostic Messages |
|
| |
|
|
|
|
Message | Meaning |
| Action Required |
|
|
| |
No message | 1) Spa temperature is unknown. | 1) After pump has been running for 2 minutes | |
on display |
|
| temperature will be displayed. |
| 2) Spa is in Economy or Sleep | 2) In Economy or Sleep mode, the pump may be off | |
| mode. |
| for hours outside a filter cycle. If you wish to see the |
|
|
| current spa temperature, either switch to Standard |
|
|
| mode or turn Jets1 on for at least two minutes. |
| 3) Power has been cut off to the | 3) The control panel will be disabled until power | |
| spa. |
| returns. Spa settings and time of day will be |
|
|
| preserved for 30 days with a battery |
|
|
| |
BUF | Internal problem detected. | Repair required. Contact your dealer or service | |
|
|
| organization. |
|
|
| |
dr | Insufficient water detected in | Check water level in spa. Refill if necessary. Make | |
| heater. Spa will be shut down for | sure pumps are been primed and filter cartridges are | |
| 15 minutes. |
| clean. Press any button to reset or wait 15 minutes |
|
|
| and spa will automatically reset. If message spa does |
|
|
| not reset, call your dealer or service organization. |
|
|
| |
dry | Insufficient water detected in | Follow directions for dr message and press any button | |
dY | heater. Spa is shut down. | to reset spa. Spa will not automatically reset when dry | |
| (Displays on third occurrence of dr | or dY is displayed. | |
|
| ||
| message.) |
|
|
|
|
| |
Ec | Indicates heater is in Economy | None. | |
| Mode. |
|
|
| Temperature unknown |
| After the pump has been running for two minutes, the |
|
|
| temperature will be displayed. |
|
|
| |
HL | A difference in readings between | Make sure spa is filled to proper level and that | |
HFL | temperature sensors has been | pumps are primed and filter cartridges are clean. If | |
| detected indicating a possible water | message does not reset, call your dealer or service | |
| flow problem. |
| organization. |
|
|
| |
IC | Potential freeze condition detected. | No action required. The pumps and the blower will | |
ICE |
|
| automatically activate regardless of spa status. |
|
|
|
|