Operation

These instructions will describe features and options that your particular spa may not be equipped with.

15 OperatingYour

Spa

Initial Start up

When first powered up, your spa will perform a self- diagnostic check and go into priming mode. When the control panel displays PR, IMMEDIATELY do the following:

1.Press the JETS 1 button to turn on the pump and let it run for 10 seconds. The pump should be running in low speed.

2.Press the JETS 1 buttons again and let the pump run in high speed for 10 seconds.

3.Press the JETS 1 button again to turn off the pump. The pump should be left in the off position for 10 to 15 seconds.

4.Repeat steps 1 through 3 until water is flowing through all the jets and all air is removed from the plumbing.

When the spa has finished priming, the heater will be activated and the water temperature will be maintained in standard mode. The spa will heat to 100°F (37.5°C) at start up until the set temperature is changed as described below.

Temperature Adjustment

(Range 80°F to 104°F, 26°C to 40°C)

The start-up temperature is set at 100°F (37.5°C). The last measured temperature is constantly displayed on the control panel. Note that the last measured spa temperature is displayed. The displayed temperature will be updated when the pump has been running for at least two minutes.

2011 Portable Spa

Auxiliary controls for the 9800 system

Press the “UP” or “DOWN” buttons once to display the set temperature. Each time either button is pressed again, the set temperature will increase or decrease depending on which button is pressed. After three seconds, the control panel will automatically display the last measured spa temperature.