Cal Spas LTR20111000 Time, Standard, Economy, Sleep, and Standby Modes, Jets, Option, Invert

Models: LTR20111000

1 56
Download 56 pages 16.11 Kb
Page 18
Image 18
Time

16

Operating SpaYour

Time

When time hasn’t been programmed, the “TIME” icon flashes. To set the time, press the “TIME” button and then the “MODE/PROG” button. Use the “UP” and “DOWN” buttons to adjust time. See the next page for more detailed instructions.

Standard, Economy, Sleep, and Standby

Modes

Mode/Prog: This button is used to switch between standard, economy, and sleep modes.

1. Press “MODE/PROG” to enter mode programming.

2.Press the “DOWN” button to cycle through to the desired mode.

3.Press “MODE/PROG” to confirm selection.

StandardMode:Standard mode maintains the desired temperature. The last measured spa temperature displayed is current only when the pump has been running for at least two minutes. STAND will display until the mode is changed.

Economy Mode: Economy mode heats the spa to the set temperature only during filter cycles. ECON will display until the mode is changed. Pressing the “JETS 1” button while in economy mode puts the spa in standard-in-economy mode, which operates the same as standard mode but reverts back to economy mode automatically after one hour. During this time, pressing the “MODE/PROG” button will revert to economy mode immediately.

Sleep Mode: Sleep mode heats the spa to within 20°F (11°C) of the set temperature only during filter cycles. SLEEP will display until the mode is changed.

Standby Mode: Pressing “Warm” or “Cool” then “JETS 2” will turn off all spa functions temporarily. This is helpful when changing a filter. Pressing any button resets the spa.

Jets 1

Press the “JETS 1” button once to turn pump 1 on or off and to shift between low and high speeds if equipped. If left running, the low speed turns off after two hours and the high speed turns off after 15 minutes. On non-circulation systems, the low speed of pump 1 runs when the blower or any other pump is on. It may also activate for at least two minutes every 30 minutes to detect the spa temperature and then to heat to the set temperature if needed, depending upon the mode. When the low speed turns on automatically, it cannot be deactivated from the panel; however, the

high speed may be started.

Jets 2

Press the “JETS 2” button once to turn pump 2 on or off and to shift between low and high speeds if it is a two-speed pump. If left running, the pump will turn off after 15 minutes.

Option

This is an optional feature. Press the “OPTION” button to turn the optional equipment on and off. If left on, the equipment will automatically turn off after 15 minutes.

Light

Press the “LIGHT” button to turn the spa light on and off and to shift between dim and bright settings if your light is dimmable. On dim, the control panel will show the center circle plus one quarter of the light beams. Half of the light beams will show on medium brightness, and all of the light beams will show on bright.

Invert

Press the “INVERT” button to change the numbers in the display to read upside down. Another press returns the display to the right-side-up position. This enables you to read the display while you are in the spa.

Locking the Panel

To lock the panel:

Press “TIME”, “JETS 1”, and the “UP” button within three seconds. When locked, the panel will display “LOCK”. All buttons are frozen except the “TIME” button.

To unlock the panel:

Press “TIME”, “JETS 1” then the “DOWN” button within three seconds.

Setting the Temperature Lock

To activate the temperature lock:

Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, then the “UP” button within three seconds. The panel will display “TEMP LOCK” when the set temperature is locked.

To unlock the set temperature:

Press the “UP” or “DOWN” button, “TIME”, “JETS 1”, and then the “DOWN” button.

2011 Portable Spa

www.calspas.com

LTR20111000, Rev. D

Page 18
Image 18
Cal Spas LTR20111000 Time, Standard, Economy, Sleep, and Standby Modes, Jets, Option, Invert, Locking the Panel, Light