Symptom

Pressure washer does not start up

cause

1.GFCI has tripped

2.Plug is not well connected or electric socket is faulty

3.Extension cord too long or wire size too small

4.Main voltage supply too low

5.Unit breaker tripped

solution

1.Push reset button on plug

2.Check plug and socket

3.Remove extension cord

4.Check that main supply voltage is adequate

5.Turn off unit and wait approximately 20 minutes for breaker to reset.

Motor stops suddenly

1.

Extension cord too long or wire size

1.

Remove extension cord

 

 

too small

 

 

 

2.

Unit breaker tripped

2.

Turn off unit and wait approximately 20 minutes

 

 

 

 

for breaker to reset.

 

 

 

Unit begins to smoke

Overheated, overloaded or damaged

Turn off unit and call 1-800-330-0712

 

motor

 

 

 

 

 

 

 

Pump noisy / pump runs

1.

Pump drawing in air/low water supply

1.

Ensure fittings are tight. Increase water pressure

rough

2.

Valves dirty or worn

2.

Check, clean or replace

 

 

3.

Worn bearings

3.

Check and replace

 

4.

Water too hot

4.

Reduce temperature below 100° F

 

 

 

 

 

Pressure washer will not spray

1.

Not using soap tip

1.

Install 65° (black) soap tip

detergent

2.

Clog, kink, or hole in detergent

2.

If clean, unkink or replace hose.

 

 

 

suction hose

 

 

 

3.

Hose length too long

3.

Use only hose length provided with initial

 

 

 

 

purchase of pressure washer. Detergent suction

 

 

 

 

will not function if more than one section of hose

 

 

 

 

is attached to unit.

 

4.

Lance not functioning properly

4.

Remove lance from gun. If detergent is dispensed

 

 

 

 

through gun, the lance must be replaced. If no

detergent is dispensed through gun, remove

1 inch tapered detergent barb from pump. Clean the barb, and make sure that ball and spring are properly aligned with tapered portion of the spring facing the ball. The ball should be on top of the spring.