Section 3. TLX106 Instrumentation Installation
Earth
Ground
Stand off
Connector Sensors
#4 | TEMP | |
CS615 | ||
| ||
#2 | WS/WD | |
#6 | SDI 12 | |
GYP BLOCK | ||
| ||
#7 | TEMP | |
#5 | RAIN | |
(PRECIP) | ||
| ||
#1 | TEMP / RH | |
#3 | SOLAR | |
RADIATION | ||
| ||
#8 | COMM |
CS I/O
POWER CABLE PORT
STAND OFF
COAXIAL CONNECTION
FIGURE
3)Replace the protective connector cover after sensors are connected and power and communications cables are installed. Ensure that all cables and connector caps are under the cover before tightening the screws.
4)Configure sensor switch settings as shown in Figure
604 Ohm | (LI190SB) |
Open | (LI1200X) |
100 Ohm | (LI200S) |
1 K | (HMP35C) |
Open | (CS500, HMP45C) |
Open |
|
SW 12V (CS500, HMP45C)
Open (HMP35C) 5V
FIGURE
3.3 Communication and Data Storage Peripherals
One communications kit can be mounted to the TLX106 Enclosure back plate. Communication kits ordered with the TLX106 Enclosure are