Section 3. TLX106 Instrumentation Installation
3.Connect the SC932C
4.Wire the Rad Modem to the TLX106 Enclosure with the 12 inch patch cord. Match wire labels to wiring panel labels on both the TLX106 Enclosure and the Rad Modem (+XMT to +XMT, etc.). A small screw driver in provided with the TLX106 Enclosure to access the Rad Modem connections.
3.3.2.2External InstallationThe following
At the TLX106 Enclosure:
(1)20 foot
(2)2 Direct Burial Splice Kits
(1)Length of User Supplied Wire (Supplier: Anixter, p/n
At the PC:
(1) Rad Modem
(1) 5 foot
(1)10 foot 14 AWG Ground Wire
(1)Surge Protector and Case
1)Connect the 20 foot patch cable to the connector marked "comm" on the external back panel of the TLX106 Enclosure. Splice this cable to the user supplied cable, using the direct burial splice kits.
2)Mount the surge protector to a flat surface near the PC's serial port. Ground the center terminal to an earth (or building) ground using the 14 AWG wire.
3)Connect the 5 foot patch cord to the Rad Modem. Fasten the cable to the strain relief tab with a cable tie. Connect the Rad to the PC's serial port either directly (25 pin port) or through a 9 to 25 pin serial converter.
4)Route the