Synchronizing the Camcorder’s Time Code

You can synchronize this camcorder’s time code to an external time code generator. You can also include in the recording the user bit signal received from the TIME CODE terminal ( 48). The camcorder offers the following synchronization options.

Genlock

When a reference sync signal (analog blackburst or tri-level signal) is input through the GENLOCK terminal, the V and H phases of the camcorder’s time code will automatically be synchronized to it.

Time Code IN

Set the TIME CODE switch to IN to start the Time Code IN mode. An external SMPTE-standard LTC timing signal received from the TIME CODE terminal will be recorded as the time code on the tape. The user bit of the external timing signal can also be recorded on tape.

Time Code OUT

Set the TIME CODE switch to OUT to start the Time Code OUT mode. The camcorder’s internal time code is sent out from the TIME CODE terminal as a standard LTC timing signal.

When [SIGNAL SETUP] [SDI OUTPUT] is set to [ON(OSD)] or [ON], the time code signal will be output also through the HD/SD SDI terminal.

When [SIGNAL SETUP] [UB OUT] is set to [HD 24P 2:3], the user bit of the time code signal will be 2:3 pulldown data (when recording in 24F mode or playing back movies that are HDV 1080/24p). In other words, when recording in 24F mode or playing back movies that are HDV 1080/24p, the signal is converted to 60i using the 2:3 pulldown method and output from the HD/SD SDI terminal. An external device can receive the data used in this conversion (2:3 pulldown data) to convert the signal to 1080/24p specifications.

*

Genlock

 

 

Time Code/User bit IN

 

 

 

 

 

 

Time Code OUT

 

 

 

 

 

 

 

Connection* In SD mode, Time ode IN is not available if you select the 24F frame rate (the mode will be canceled and the “TC-(IN OUT)” display on the side panel will disappear).

Diagram

When synchronizing the camcorder to an external signal, input a reference video signal through the GENLO K terminal or a time code signal through the TIME CODE terminal. To input a time code signal through the TIME ODE terminal, set the TIME CODE switch to IN. To output a time code signal, set the switch to OUT.

 

TIME CODE switch

 

SMPTE-standard

Reference video

LTC timing signal

signal*

 

GENLOCK

TIME CODE

*As a reference video signal input you can use either an HD Y signal or an NTSC composite video signal when recording in HD.