Appendix

Status Read Command

Format

The command is sent from PC to the projector with the format below;

'CR' [Command] 'CR'

Command: one character (refer to the command table below.

The projector decodes the command and returns the 'Charactor string' with the format below;

Command

Function

Projector

Projectro status

Return

 

 

 

 

 

 

 

 

 

00

Power On

 

 

80

Stand-by mode

 

 

40

Countdown

 

 

20

Cooling down

 

 

10

Power Malfunction

 

 

28

Cooling down at the temperature abnormally

CR0

Status Read

24

Cooling down at Power Management mode

 

 

04

Power Management mode after Cooling down

 

 

21

Cooling down after the projector is turned off when the lamps

 

 

are out.

 

 

 

 

 

81

Stand-by mode after Cooling down when the lamps are out.

 

 

88

Stand-by mode after Cooling down at the temperature

 

 

abnormally.

 

 

 

 

 

 

 

 

 

 

S1 = Temperature at Sensor 1 (˚C)

 

 

 

S2 = Temperature at Sensor 2 (˚C)

 

 

 

S3 = Temperature at Sensor 3 (˚C)

CR6

Temperature Read

S1 S2 S3

(ex.) S1 = 12.3˚C, S2 = 23.4˚C, S3 = 34.5˚C

 

 

 

 

--> The projector displays “12.3 23.4 34.5”

 

 

 

(For each sensor, two digit and the tenth place numbers are

 

 

 

displayed with a space between each temperature.)

 

 

 

 

 

 

?

Communication failure

The tables on page 79 and 80 show the typical command lists for controlling the projector. Please consult your local dealer for further information of other commands.