NOTE

If a roller on the feed unit becomes loose (Figure A), re-attach it as shown in Figure B.

Before you return the upper unit to its original position, be sure to lower the lever on the feed unit (Figure B). If the document is scanned with the lever at the up position, a paper feed error will occur.

 

3. Lower the lever.

 

 

2. Press this part.

1. Fit into the

 

deeper of the

 

 

 

 

two grooves.

(A)

(B)

 

9 To close the feed unit, push the feed unit inwards as far as possible, and then release the upper unit.

When you release the feed unit, it begins to slowly fall down. Do not apply unnecessary force to push the feed unit down. Doing so might damage the scanner.

Backup

Manual

Auto

Semi-Auto

10 When the feed unit has fallen as far as it can go, press down firmly on both sides to close it.

If you press the feed unit down on only one side, the opposite side will not be fully closed. Make sure that you hear it click into place.