CHAPTER 6 FIXING SYSTEM

6–2

COPYRIGHT
©
1998 CANON INC. CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
B. Controlling the Fixing Temperature

The copier uses two thermistors mounted at the rear ends of the upper roller to monitor

surface temperature. When copies are made continuously using sheets of B4 or less, the

temperature of the area (center) coming into contact with the paper will be lower than the

temperature of the areas (ends) not coming into contact with the paper. To prevent such a

problem, the target temperature is varied in steps to suit the width of copy paper and the

temperature detected by the thermistor during copying operation.

To improve fixing on rough surface paper or tracing paper, a special paper mode (U13) has

been added to user mode, thereby enabling a target temperature unique to these types of paper.

Paper Width >257 mm

Table 6-101

257 mm > Paper Width > 216 mm

Table 6-102

216 mm > Paper Width > 182 mm

Table 6-103

Temperature detected by
thermistor at Start key on
Target temperature immediately
after Start key on Target temperature during
continuous copying (upper limit)
Less than 170°C
170°C or more, less than 180°C
180°C or more, less than 190°C
190°C or more
179°C
188°C
193°C
193°C
196°C
201°C
206°C
211°C
169°C
178°C
183°C
183°C
193°C 211°C 183°C
General plain paper
Paper with rough surface
Tracing paper General plain paper
Paper with rough surface
Tracing paper
Temperature detected by
thermistor at Start key on
Target temperature immediately
after Start key on Target temperature during
continuous copying (upper limit)
Less than 170°C
170°C or more, less than 180°C
180°C or more, less than 190°C
190°C or more
171°C
181°C
181°C
181°C
196°C
200°C
206°C
209°C
161°C
171°C
171°C
171°C
181°C 209°C 171°C
General plain paper
Paper with rough surface
Tracing paper General plain paper
Paper with rough surface
Tracing paper
Temperature detected by
thermistor at Start key on
Target temperature immediately
after Start key on Target temperature during
continuous copying (upper limit)
Less than 170°C
170°C or more, less than 180°C
180°C or more, less than 190°C
190°C or more
177°C
186°C
192°C
200°C
196°C
202°C
207°C
214°C
167°C
176°C
182°C
190°C
200°C 214°C 190°C
General plain paper
Paper with rough surface
Tracing paper General plain paper
Paper with rough surface
Tracing paper