10–102
COPYRIGHT
©
1998 CANON INC. CANON NP7161/NP7160 REV.0 AUG. 1998 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 10 TROUBLESHOOTING
Note:
1. When the diagnostic function has turned on, the copier can be reset by turning it off
once. This, however, does not apply to E000, E001, E002, E003, or E004.
This is to prevent the user from resetting the copier easily when the error is caused by
an open circuit in the thermistor, otherwise overheating and damaging the fixing
roller.
Normally, the copier will automatically turn off in about 4 sec if it is turned on
without clearing E000 through E004.
To clear E000 through E004, operate as follows:
1) Select ‘412’ (clear E000–E004) in service mode.
• The copier’s control panel indicates the respective error code.
2) Press the Start key.
3) The copier will automatically turn off, clearing the error.
2. E202 may be checked using ‘108’ in service mode (error history indication).