CHAPTER 10 TROUBLESHOOTING
10–4912.E220
Lamp regulator PCB
DC controller PCB
1
2
YES
NO
YES
Does the scanning lamp (LA1) remain off?
Set the meter range to 30 VDC, and connect
the probes to J211-2 (+) and J211-1 (-) on
the DC controller PCB. Is the voltage
between the terminals when the scanning
lamp turn on about 5 V?
See “The scanning lamp fails
to turn on.”
Check the wiring from the DC
controller PCB to the lamp
regulator PCB; if normal,
replace the lamp regulator
PCB.
Replace the DC controller
PCB.
Actions
ChecksStep
Cause Yes/No
13.E261
Power supply PCB
Power supply
frequency
1 YES
NO
Replace the power supply PCB. Is the
problem corrected? End.
If E261 is indicated often,
advise the user to install a
frequency stabilizer.
Actions
ChecksStep
Cause Yes/No
14.E710/E711
Malfunction
DC controller PCB
1 YES
NO
Turn off and then on the power switch. Is the
problem corrected? End.
Replace the DC controller
PCB.
Actions
ChecksStep
Cause Yes/No