START-UP CHECKLIST FOR CHILLER SYSTEMS

START-UP CHECKLIST FOR CHILLER SYSTEMS

(Remove and use for job ®le)

A. Preliminary Information

JOB NAME

LOCATION

INSTALLING CONTRACTOR

DISTRIBUTOR

START-UP PERFORMED BY

EQUIPMENT: Chiller: MODEL #

 

 

 

 

 

 

 

 

SERIAL #

 

COMPRESSORS:

 

 

 

 

 

 

 

 

 

 

 

 

 

CIRCUIT #1

 

 

 

 

CIRCUIT #2 (30HK,HL ONLY)

MODEL #

 

 

 

 

 

 

MODEL #

 

SERIAL #

 

 

 

 

 

 

SERIAL #

 

MOTOR #

 

 

 

 

 

 

MOTOR #

 

CONDENSER (30HK, HWB, HWC, HWS ONLY):

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SERIAL #

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COOLER:

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL #

 

 

MANUFACTURED BY

SERIAL #

 

 

 

 

 

DATE

 

 

AIR-HANDLING EQUIPMENT:

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUFACTURER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL #

 

 

SERIAL #

 

ADDITIONAL AIR-HANDLING UNITS AND ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

 

 

B. Preliminary Equipment Check (YES or NO)

IS THERE ANY SHIPPING DAMAGE?

 

IF SO, WHERE

WILL THIS DAMAGE PREVENT UNIT START-UP?

CHECK POWER SUPPLY. DOES IT AGREE WITH UNIT?

HAS THE CIRCUIT PROTECTION BEEN SIZED AND INSTALLED PROPERLY? (refer to Installation Instructions)

ARE THE POWER WIRES TO THE UNIT SIZED AND INSTALLED PROPERLY? (refer to Installation Instructions)

HAS THE GROUND WIRE BEEN CONNECTED?

ARE ALL TERMINALS TIGHT?

ON 30HW UNITS, IS THE THERMISTOR SECURELY STRAPPED TO THE COOLER LEAVING CHILLED FLUID LINE, AND IS IT PROPERLY INSULATED?

ON 30HW UNITS, IS YELLOW WIRE GOING TO TRANSFORMER 1 (POWER TRANSFORMER) ON THE CORRECT TERMINAL (TERMINAL H2 FOR 208 V AND 575 V; TERMINAL H3 FOR 230 V, 380 V, AND 400 V, TERMINAL H4 FOR 460 V)?

IF UNIT IS A MEDIUM TEMPERATURE BRINE UNIT, IS TEMPERATURE CONTROLLER SET FOR BRINE AND NOT FOR WATER? IF UNIT IS NOT A BRINE UNIT, IS TEMPERATURE CONTROLLER SET FOR WATER AND NOT FOR BRINE?

HAVE TEMPERATURE CONTROLLER, CONTROL MODULE AND CONTROL RELAY CONNECTIONS BEEN CHECKED FOR TIGHTNESS?

Manufacturer reserves the right to discontinue, or change at any time, speci®cations or designs without notice and without incurring obligations.

Book

2

 

PC 903

Catalog No. 533-070

Printed in U.S.A.

Form 30H-10SI

Pg CL-1

11-98

Replaces: 30H-8SI

Tab

5c

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page 41
Image 41
Carrier 30HL050 START-UP CHECKLIST FOR CHILLER SYSTEMS Remove and use for job le, A. Preliminary Information, Compressors