Carrier 30RAP010-060 a30-4948, Dimensions - 30RAP010 and 015 Units, Top View, Front View

Models: 30RAP010-060

1 40
Download 40 pages 58.51 Kb
Page 7
Image 7
TOP VIEW

UNIT

CENTER OF GRAVITY

 

UNIT HEIGHT

 

VICTAULIC CONNECTIONS

 

X

 

Y

H (STANDARD)

H (VALUE SOUND)

WATER IN/OUT

 

 

 

30RA010

18.40

[467]

37.80

[960]

66.5

[1689]

61.0

[1549]

2"

STANDARD

18.35

[466]

37.69

[957]

66.5

[1689]

61.0

[1549]

2"

30RA015

36 [914] MIN.

42 [1067]

MIN.

7

NOTES:

1.DO NOT CAP ORa30-4948 OTHERWISE OBSTRUCT THEFRONT VIEWRIGHT SIDE LIQUID LINE TEMPERATURE RELIEF. Fig. 5 — Dimensions — 30RAP010 and 015 Units

2.Manual background 7/8 [22.4] PILOT HOLE PROVIDEDManual backgroundFORManual backgroundLOCATINGManual backgroundFIELD Manual backgroundPOWER Manual backgroundWIRING. Manual background ACTUAL HOLE REQUIREDManual backgroundDEPENDSManual backgroundONManual backgroundFIELD Manual backgroundWIREManual backgroundManual background SIZING. Manual background

3.Manual background 0.437 [11.10] HOLE USED FORManual background MOUNTINGManual backgroundUNIT. Manual background

4.UNIT MUST HAVE CLEARANCESManual backgroundASManual backgroundFOLLOWS: Manual background

TOP - DO NOT RESTRICT.Manual background

COIL SIDE - 42 [1067] FROMManual backgroundSOLIDManual backgroundSURFACE. Manual background PANEL SIDE - 48 [1219] PERManual backgroundNEC. Manual background

5.SEE TABLE COLUMNManual background H;Manual background DIMENSIONManual backgroundFORManual backgroundSTANDARDManual background FAN OR VALUEManual backgroundManual background SOUND FAN OPTION.Manual background

6.CARRIERManual background DOES NOT RECOMMENDManual backgroundINSTALLATION Manual backgroundINManual backgroundManual backgroundA Manual backgroundPIT.Manual backgroundManual background

7.UNIT CAN BE HANDLEDManual backgroundUSINGManual backgroundTHEManual backgroundManual background FORK Manual backgroundManual backgroundTRUCK Manual backgroundManual backgroundLIFT POCKETS. Manual background

8.WATERManual background CONNECTIONS RECESSEDManual background2-3/8Manual backgroundINCHES Manual backgroundINSIDE UNIT.Manual backgroundManual background

9. DIMENSIONS ARE IN INCHES. DIMENSIONS IN [ ] AREManual background IN MILLIMETERSManual background

66.50 [1689.1]

48 [1219] MIN.

 

COIL

 

 

 

AREA

 

 

 

 

SERVICE

 

 

 

CLEARANCE

PANEL SIDE

 

 

BORDER

 

 

(NOT TO SCALE)

SEE NOTE #4

 

 

 

 

 

 

 

CG

 

 

 

 

AIR FLOW

 

Y

 

COIL SIDE

 

 

 

 

 

 

SEE NOTE #4

 

 

X

 

 

 

TOP VIEW

36 [914] MIN.

 

 

 

AIR FLOW

CONTROL BOX

HINGED ACCESS

SERVICE

ACCESS

WATER-OUTManual backgroundManual background

COMPRESSORManual background

WATER-IN

ACCESS

9.52

[241.8]

FIELD CONTROL WIRING CONNECTIONS

 

40.50 [1028.7]

RADIUS

20 [508]

 

CONTROL BOX

 

HINGED ACCESS

 

 

7/8

[22.4]

 

FIELD POWER ENTRY

 

SEE NOTE #2

 

4.61

 

 

[117.1]

 

 

24.85

 

 

[631.2]

 

HManual backgroundManual background

SEE NOTE #5

VALUE SOUND FAN OPTION

(PICTORIALLY)

a30-4948

1.00[25.4] Manual backgroundManual background SEE NOTE #3

TYP.

9.68[245.9] Manual background

15.43[391.9] Manual background

Manual backgroundManual background 1.00 [25.4]

SEE NOTE #3

TYP.

FORK

TRUCK

POCKETS

FRONT VIEW

1.50

[38.1]

1.50

[38.1]

RIGHT Manual backgroundSIDE

VIEW

Fig. 5 — Dimensions — 30RAP010 and 015 Units