Table 4 Ð Electrical Data (cont)

UNIT

NOMINAL

VOLTAGE

COMPRESSOR

 

OFM

 

 

IFM

POWER

COMBUSTION

 

POWER SUPPLY

RANGE

No. 1

No. 2

 

 

 

EXHAUST

FAN MOTOR

 

SIZE

VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

48E

(3 Ph 60 Hz)

Min

Max

RLA

LRA

RLA

LRA

Qty

Hp

 

FLA

Hp

 

FLA

FLA

LRA

FLA

 

MCA

 

MOCP*

 

 

 

(ea)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

46.2/

Ð

Ð

0.96

 

223.1/218.9

 

275/275

 

 

 

 

 

 

 

 

 

 

 

 

 

42.0

23.6

41.6

0.96

 

246.7/242.5

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230

187

254

69.2

345

69.2

345

4

1

 

5.3

20

 

59.4/

Ð

Ð

0.96

 

236.3/230.9

 

300/300

 

 

 

54.0

23.6

41.6

0.96

 

259.9/254.5

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

74.8/

Ð

Ð

0.96

 

251.7/244.9

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

68.0

23.6

41.6

0.96

 

275.3/268.5

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

21.0

Ð

Ð

0.50

 

96.6

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

109.2

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

044

460

414

508

28.8

173

28.8

173

4

1

 

2.7

20

 

27.0

Ð

Ð

0.50

 

102.6

 

125

 

 

12.6

23.6

0.50

 

115.2

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

34.0

Ð

Ð

0.50

 

109.6

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

122.2

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

17.0

Ð

Ð

0.50

 

86.7

 

110

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

99.3

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

518

632

26.7

120

26.7

120

4

1

 

2.4

20

 

22.0

Ð

Ð

0.50

 

91.7

 

110

 

 

 

12.6

23.6

0.50

 

104.3

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

27.0

Ð

Ð

0.50

 

96.7

 

110

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

109.3

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

59.4/

Ð

Ð

0.96

 

252.4/247.0

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

54.0

23.6

41.6

0.96

 

276.0/270.6

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230

187

254

82.1

446

69.2

345

4

1

 

5.3

25

 

74.8/

Ð

Ð

0.96

 

267.8/261.0

 

300/300

 

 

 

68.0

23.6

41.6

0.96

 

291.4/284.6

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

88.0/

Ð

Ð

0.96

 

281.0/273.0

 

300/300

 

 

 

 

 

 

 

 

 

 

 

 

 

80.0

23.6

41.6

0.96

 

304.6/296.6

 

350/300

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

27.0

Ð

Ð

0.50

 

119.5

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

132.1

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048

460

414

508

42.3

223

28.8

173

4

1

 

2.7

25

 

34.0

Ð

Ð

0.50

 

126.5

 

150

 

 

12.6

23.6

0.50

 

139.1

 

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

40.0

Ð

Ð

0.50

 

132.5

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

145.1

 

175

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

 

22.0

Ð

Ð

0.50

 

101.6

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

114.2

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

575

518

632

34.6

164

26.7

120

4

1

 

2.4

25

 

27.0

Ð

Ð

0.50

 

106.6

 

125

 

 

 

12.6

23.6

0.50

 

119.2

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30

 

32.0

Ð

Ð

0.50

 

111.6

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

12.6

23.6

0.50

 

124.2

 

150

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

EXAMPLE: Supply voltage is 460-3-60.

FLA

Ð Full Load Amps

HACR

Ð Heating, Air Conditioning and

 

Refrigeration

IFM

Ð Indoor (Evaporator) Fan Motor

LRA

Ð Locked Rotor Amps

MCA

Ð Minimum Circuit Amps

MOCP Ð Maximum Overcurrent Protection

AB = 452 v

BC = 464 v

AC = 455 v

Average Voltage =

452 + 464 + 455

3

NEC

Ð

National Electrical Code

or

OFM

Ð

Outdoor (Condenser) Fan Motor

 

=

1371

3

RLA Ð Rated Load Amps

*Fuse or HACR circuit breaker.

NOTES:

1. In compliance with NEC requirements for multimotor and combi-

nation load equipment (refer to NEC Articles 430 and 440), the

overcurrent protective device for the unit shall be fuse or HACR

= 457

Determine maximum deviation from average voltage. (AB) 457 − 45 2 = 5 v

(BC) 464 − 45 7 = 7 v

(AC) 457 − 45 5 = 2 v Maximum deviation is 7 v.

Determine percent voltage imbalance.

breaker. Canadian units may be fuse or circuit breaker.

% Voltage Imbalance = 100 x

7

2. Unbalanced 3-Phase Supply Voltage

Never operate a motor where a phase imbalance in supply volt-

age is greater than 2%. Use the following formula to determine

the percent voltage imbalance.

% Voltage Imbalance

457

= 1.53%

This amount of phase imbalance is satisfactory as it is below the maximum allowable 2%.

IMPORTANT: If the supply voltage phase imbalance is more than

= 100 x

max voltage deviation from average voltage

average voltage

2%, contact your local electric utility company immediately.

20

Page 20
Image 20
Carrier 48EJ, EW, EK, EY024-048 Qty, 044, Heating, Air Conditioning, Minimum Circuit Amps, RLA Ð Rated Load Amps

EW, EY024-048, EK, 48EJ specifications

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 are cutting-edge rooftop air conditioning units designed for commercial applications. These models are renowned for their reliability, energy efficiency, and innovative technologies aimed at providing optimal indoor comfort.

One of the standout features of these units is their advanced cooling and heating capabilities. They employ a multi-stage compressor system that allows for precise temperature control, accommodating various load requirements. This flexibility is particularly beneficial in commercial settings where the cooling load can fluctuate throughout the day.

Energy efficiency is paramount in today’s environmental landscape, and Carrier has ensured that these models meet stringent efficiency standards. They incorporate high-efficiency scroll compressors, which significantly reduce energy consumption while delivering powerful performance. The units are also equipped with variable speed fans that adjust airflow based on demand, further optimizing energy use.

In terms of construction, these rooftop units feature a robust design that enhances durability and longevity. The cabinet is constructed to withstand harsh weather conditions, ensuring reliable performance year-round. Additionally, the units are equipped with corrosion-resistant coatings, particularly useful in coastal environments where salt exposure can be a concern.

The Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY models utilize advanced controls and connectivity features, allowing for easy integration into building management systems. This connectivity enables remote monitoring and control, facilitating quick response to changing conditions and simplifying maintenance tasks.

Noise reduction is another key characteristic of these models. They are designed with sound-absorbing insulation and low-noise fan blades to ensure quiet operation, making them suitable for noise-sensitive environments such as schools and hospitals.

These units are also available with various options for air filtration and dehumidification. The use of high-efficiency air filters enhances indoor air quality by trapping dust, pollen, and other airborne particles. Enhanced dehumidification capabilities ensure that spaces remain comfortable even in humid conditions.

In conclusion, the Carrier 48EJ, 48AW, 48EK, 48AJ, and 48EY024-068 rooftop units are engineered to offer exceptional performance, energy efficiency, and durability. With their advanced technologies and user-friendly features, they stand out as reliable solutions for meeting diverse commercial cooling and heating needs, making them a popular choice for many businesses.