Carrier Performance Data-Standardecm Indoor Motor, Heating Capacity 50XT042 High, Dry Bulb

Models: 50XT

1 38
Download 38 pages 34.13 Kb
Page 21
Image 21
Heating Capacity

PERFORMANCE DATA-STANDARD ECM INDOOR MOTOR

Heating Capacity

50XT042 High

INDOOR AIR

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)

 

 

 

 

 

 

 

 

-10 (-23.3)

 

 

0 (-17.7)

 

 

10 (-12.2)

 

 

17 (-8.3)

 

 

20 (-6.6)

 

EDB

 

Capacity

 

Total

Capacity

 

Total

Capacity

 

Total

Capacity

 

Total

Capacity

 

Total

_F

CFM

MBtuh

 

System

MBtuh

 

System

MBtuh

 

System

MBtuh

 

System

MBtuh

 

System

(_C)

 

 

 

 

KW

 

 

 

KW

 

 

 

KW

 

 

 

KW

 

 

 

KW

 

Total

Integ

Total

Integ

Total

Integ

Total

Integ

Total

Integ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

1225

10.65

9.80

 

2.06

13.99

12.87

 

2.19

17.85

16.39

 

2.32

21.02

19.17

 

2.41

22.53

20.43

 

2.46

(15.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

10.79

9.92

 

2.08

14.15

13.02

 

2.20

18.04

16.56

 

2.32

21.26

19.39

 

2.41

22.79

20.67

 

2.45

70

1225

10.16

9.34

 

2.28

13.49

12.42

 

2.42

17.32

15.89

 

2.55

20.37

18.58

 

2.66

21.80

19.77

 

2.70

(21.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

10.32

9.49

 

2.29

13.66

12.57

 

2.42

17.52

16.08

 

2.55

20.60

18.78

 

2.65

22.06

20.01

 

2.69

80

1225

9.53

8.77

 

2.49

12.89

11.86

 

2.64

16.69

15.32

 

2.80

19.70

17.96

 

2.91

21.10

19.14

 

2.96

(26.7)

1400

9.69

8.92

 

2.51

13.07

12.03

 

2.65

16.90

15.51

 

2.80

19.94

18.18

 

2.90

21.36

19.37

 

2.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50XT042 High Con’t.

 

INDOOR AIR

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C)

 

 

 

 

 

 

 

 

 

 

 

30 (-1.1)

 

 

40 (4.4)

 

 

47 (8.3)

 

 

50 (10)

 

 

60 (15.5)

 

 

EDB

 

 

Capacity

 

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

 

Total

 

 

_F

 

CFM

MBtuh

 

System

MBtuh

System

MBtuh

System

MBtuh

System

MBtuh

 

System

 

(_C)

 

 

 

 

 

KW

 

 

KW

 

 

KW

 

 

KW

 

 

 

KW

 

 

Total

Integ

Total

Integ

Total

Integ

Total

Integ

Total

Integ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60

 

1225

28.26

24.77

 

2.62

35.01

35.01

2.81

40.36

40.36

2.97

42.96

42.96

3.05

51.37

51.37

 

3.25

 

(15.6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

1400

28.60

25.06

 

2.60

35.38

35.38

2.79

40.37

40.37

2.91

43.00

43.00

2.96

51.50

51.50

 

3.19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

70

 

1225

27.38

23.99

 

2.87

33.83

33.83

3.06

39.05

39.05

3.22

41.60

41.60

3.31

50.54

50.54

 

3.54

 

(21.1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1400

27.71

24.28

 

2.85

34.27

34.27

3.03

39.50

39.50

3.20

41.96

41.96

3.27

50.80

50.80

 

3.48

 

 

80

 

1225

26.37

23.10

 

3.13

32.67

32.67

3.34

37.72

37.72

3.50

40.19

40.19

3.59

49.42

49.42

 

3.92

 

(26.7)

 

1400

26.72

23.41

 

3.11

33.12

33.12

3.30

38.23

38.23

3.46

40.71

40.71

3.55

49.70

49.70

 

3.78

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cap.— Heating Capacity (1000 Btuh) (Includes Indoor-Fan Motor Heat)

 

 

 

 

 

 

 

 

 

 

 

db

— Dry Bulb

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

kW — Total Power Input (Includes Compressor Motor Power Input Outdoor-Fan Motor Input, and Indoor-Fan Motor Input)

 

 

 

 

 

 

rh

— Relative Humidity

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it.

 

 

 

 

 

50XT

Page 21
Image 21
Carrier manual Performance Data-Standardecm Indoor Motor, Heating Capacity 50XT042 High, 50XT042 High Con’t, Dry Bulb