PHYSICAL DATA

50XT

PHYSICAL DATA

UNIT SIZE

024

030

036

 

042

048

060

NOMINAL CAPACITY (ton)

2

2---1/2

3

 

3---1/2

4

5

OPERATING WEIGHT (lb)

405

435

464

 

476

492

535

(kg)

184

197

210

 

216

223

243

 

 

 

 

 

 

 

COMPRESSOR

 

 

Two---Stage Scroll

 

 

REFRIGERANT: PURON (R---410A) Quantity (lb)

10.3

11.5

9.7

 

14.0

15.5

16.0

(kg)

4.7

5.2

4.4

 

6.4

7.0

7.3

 

 

 

 

 

 

 

EXPANSION DEVICE ---HEATING

 

 

AccuRater

 

 

ORIFICE OD (in.) --- Left

0.042

0.038

0.035

 

0.040

0.038

0.046

ORIFICE OD (in.) --- Right

0.038

0.035

 

0.042

0.046

0.046

 

 

EXPANSION DEVICE ---COOLING

 

 

 

TXV

 

 

Size

2 Ton

3 Ton

3 Ton

 

4 Ton

4 Ton

5 Ton

Part Number

 

 

 

 

 

 

 

EA36YD129

EA36YD139

EA36YD139

 

EA36YD149

EA36YD149

EA36YD159

OUTDOOR COIL

 

 

 

 

 

 

 

RowsFins/in.

221

221

221

 

221

221

221

Face Area (sq. ft.)

13.6

15.3

17.5

 

19.4

19.4

23.3

 

 

 

 

 

 

 

 

OUTDOOR FAN

 

 

 

 

 

 

 

Nominal Cfm

2700

2700

2800

 

2800

3300

3300

Diameter (in.)

22

22

22

 

22

22

22

(mm)

559

559

559

 

559

559

559

Motor HP (RPM)

1/8 (825)

1/8 (825)

1/8 (825)

 

1/8 (825)

1/4 (1100)

1/3 (1110)

INDOOR COIL

 

 

 

 

 

 

 

RowsFins/in.

317

317

317

 

317

317

417

Face Area (sq. ft.)

3.7

3.7

4.7

 

4.7

5.7

5.7

 

 

 

 

 

 

 

 

INDOOR FAN

 

 

 

 

 

 

 

Nominal Airflow (Cfm)

 

 

 

 

 

 

 

Comfort

Variable

based on Comfort

Settings (see User Interface instructions for more information).

Efficiency

700

875

1050

 

1225

1400

1750

Max

800

1000

1200

 

1400

1600

2000

Size (in.)

10x10

10x10

11x10

 

11x10

11x10

11x10

(mm)

254x254

254x254

279x254

 

279x254

279x254

279x254

Motor HP (RPM)

1/2

1/2

3/4

 

3/4

3/4

1

HIGH---PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

Cutout

 

 

670 ± 10

 

 

Reset (Auto)

 

 

470 ± 25

 

 

 

 

 

 

 

 

 

 

HIGH---PRESSURE SWITCH 2 (psig)

 

 

 

 

 

 

 

(Compressor Solenoid)

 

 

 

 

 

 

 

Cutout

 

 

565 ± 15

 

 

Reset (Auto)

 

 

455 ± 15

 

 

 

 

 

 

 

 

 

 

LOSS ---OF---CHARGE/LOW---PRESSURE SWITCH

 

 

 

 

 

 

 

(Liquid Line) (psig)

 

 

 

 

 

 

 

Cutout

 

 

 

23 ± 5

 

 

Reset (Auto)

 

 

 

55 ± 5

 

 

RETURN---AIR FILTERS Throwaway (in.)*

20x24x1

24x30x1

 

 

24x36x1

 

(mm)

508x610x25

610x762x25

 

 

610x914x25

 

 

 

 

 

 

 

 

 

*Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. WC.

ISO 9001:2000

REGISTERED

A-WEIGHTED SOUND POWER LEVEL (dBA)

 

 

 

 

 

MODEL 50XT

STANDARD

 

TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment)

 

RATING

 

 

 

 

 

 

 

 

(dBA)

125

250

500

1000

2000

4000

8000

 

 

 

 

 

 

 

 

 

024

75

58.8

63.5

67.2

66.9

63.7

58.3

50.0

 

 

 

 

 

 

 

 

 

030

75

58.8

63.5

67.2

66.9

63.7

58.3

50.0

 

 

 

 

 

 

 

 

 

036

75

60.7

63.3

66.8

66.5

64.2

60.3

53.0

 

 

 

 

 

 

 

 

 

042

75

56.7

62.8

67.8

67.4

63.7

57.7

50.8

 

 

 

 

 

 

 

 

 

048

78

62.4

69.9

71.3

73.4

70.0

66.3

60.1

 

 

 

 

 

 

 

 

 

060

78

63.5

67.6

71.8

75.5

71.0

68.1

59.9

NOTE: Tested in accordance with ARI Standard 270---95 (not listed in ARI).