COOLING PERFORMANCE (cont)

52PQ 12,000 NOMINAL BTUH MODELS

Evaporator entering air temp. — 80 F Evap. air — 350 CFM

TEMP (F) AIR ENT.

 

EVAP AIR — EWB (F)

 

COND (40% RH)

57.00

 

62.00

67.00

 

72.00

 

MBtuh

11.79

 

11.95

12.65

 

13.17

80

kW

0.97

 

0.97

0.95

 

0.93

 

I

4.29

 

4.27

4.17

 

4.08

 

MBtuh

11.60

 

11.74

12.48

 

12.97

85

kW

1.02

 

1.02

1.00

 

0.97

 

I

4.49

 

4.48

4.38

 

4.27

 

MBtuh

11.39

 

11.49

12.28

 

12.79

90

kW

1.07

 

1.07

1.04

 

1.02

 

I

4.69

 

4.68

4.59

 

4.48

 

MBtuh

11.17

 

11.24

12.05

 

12.58

95

kW

1.12

 

1.12

1.09

 

1.07

 

I

4.90

 

4.90

4.80

 

4.69

 

MBtuh

11.66

 

10.97

11.78

 

12.33

100

kW

1.17

 

1.17

1.14

 

1.12

 

I

5.12

 

5.12

5.02

 

4.91

 

MBtuh

12.16

 

10.70

11.50

 

12.04

105

kW

1.22

 

1.22

1.20

 

1.17

 

I

5.34

 

5.34

5.25

 

5.13

 

MBtuh

12.69

 

10.45

11.17

 

11.75

110

kW

1.27

 

1.27

1.25

 

1.22

 

I

5.57

 

5.57

5.48

 

5.36

 

MBtuh

13.23

 

10.19

10.83

 

11.39

115

kW

1.32

 

1.32

1.30

 

1.27

 

I

5.81

 

5.81

5.72

 

5.59

LEGEND

EWB — Entering Wet Bulb

ICompressor Current Amps

kW

Total Power

MBtuh

Total Cooling Capacity (Btuh in thousands)

RH

Relative Humidity

NOTES:

1.Total current (I) based on 230-volt system.

2.Evaporator entering dry bulb air temperature is 80 F.

ALL 15,000 NOMINAL BTUH MODELS

Evaporator entering air temp. — 80 F Evap. air — 320 CFM

TEMP (F) AIR ENT.

 

EVAP AIR — EWB (F)

 

COND (40% RH)

57.00

 

62.00

67.00

 

72.00

 

MBtuh

 

14.77

15.82

 

16.74

80

kW

 

1.39

1.36

 

1.33

 

I

 

6.09

6.00

 

5.85

 

MBtuh

 

14.55

15.63

 

16.59

85

kW

 

1.45

1.43

 

1.40

 

I

 

6.38

6.27

 

6.14

 

MBtuh

 

14.20

15.39

 

16.39

90

kW

 

1.53

1.49

 

1.46

 

I

 

6.72

6.56

 

6.43

 

MBtuh

12.98

 

13.85

15.08

 

16.15

95

kW

1.67

 

1.61

1.56

 

1.53

 

I

7.32

 

7.05

6.85

 

6.73

 

MBtuh

12.78

 

13.51

14.79

 

15.85

100

kW

1.74

 

1.68

1.63

 

1.60

 

I

7.63

 

7.37

7.16

 

7.03

 

MBtuh

12.51

 

13.03

14.39

 

15.48

105

kW

1.81

 

1.75

1.70

 

1.67

 

I

7.95

 

7.68

7.48

 

7.35

 

MBtuh

12.24

 

12.54

13.91

 

15.04

110

kW

1.88

 

1.82

1.78

 

1.75

 

I

8.27

 

8.00

7.80

 

7.67

 

MBtuh

11.95

 

12.05

13.54

 

14.53

115

kW

1.96

 

1.89

1.85

 

1.82

 

I

8.62

 

8.32

8.14

 

8.00

LEGEND

EWB — Entering Wet Bulb

ICompressor Current Amps

kW

Total Power

MBtuh

Total Cooling Capacity (Btuh in thousands)

RH

Relative Humidity

NOTES:

1.Total current (I) based on 230-volt system.

2.Evaporator entering dry bulb air temperature is 80 F.

COOLING SENSIBLE HEAT FACTORS (SHF) AT 80 F INDOOR DB

MODEL

INDOOR WB

 

 

OUTDOOR AMBIENT DB TEMPERATURE (F)

 

 

52PC,PE,PQ,CE,CQ

(F)

80

85

 

90

95

100

105

 

110

115

All 7,000

57

0.91

0.91

 

0.91

0.91

0.91

0.90

 

0.90

0.90

62

0.89

0.90

 

0.91

0.91

0.92

0.92

 

0.91

0.91

Nominal Btuh

 

 

67

0.71

0.72

 

0.72

0.74

0.74

0.75

 

0.76

0.77

Models

 

 

72

0.53

0.53

 

0.54

0.54

0.54

0.55

 

0.55

0.56

 

 

 

All 9,000

57

0.93

0.93

 

0.93

0.93

0.92

0.92

 

0.92

0.92

62

0.86

0.87

 

0.88

0.89

0.90

0.91

 

0.92

0.92

Nominal Btuh

 

 

67

0.67

0.67

 

0.68

0.70

0.70

0.70

 

0.71

0.72

Models

 

 

72

0.51

0.51

 

0.51

0.51

0.52

0.52

 

0.52

0.53

 

 

 

52CQ 12,000

57

0.94

0.94

 

0.94

0.94

0.94

0.94

 

0.94

0.94

52

0.88

0.89

 

0.91

0.92

0.93

0.93

 

0.93

0.93

Nominal Btuh

 

 

67

0.69

0.69

 

0.70

0.70

0.71

0.72

 

0.73

0.74

Models

 

 

72

0.50

0.51

 

0.52

0.52

0.53

0.53

 

0.54

0.54

 

 

 

52CE,PC,PE 12,000

57

0.92

0.91

 

0.90

0.90

0.90

0.90

 

0.90

0.90

62

0.89

0.89

 

0.90

0.90

0.91

0.92

 

0.92

0.92

Nominal Btuh

 

 

67

0.68

0.69

 

0.70

0.72

0.72

0.73

 

0.74

0.75

Models

 

 

72

0.51

0.51

 

0.51

0.51

0.52

0.53

 

0.53

0.54

 

 

 

52PQ 12,000

57

0.93

0.93

 

0.93

0.93

0.93

0.93

 

0.93

0.93

62

0.89

0.90

 

0.91

0.92

0.93

0.93

 

0.93

0.93

Nominal Btuh

 

 

67

0.69

0.70

 

0.71

0.71

0.72

0.73

 

0.74

0.75

Models

 

 

72

0.51

0.51

 

0.52

0.52

0.53

0.53

 

0.53

0.54

 

 

 

All 15,000

57

 

0.91

0.91

0.91

 

0.91

0.90

62

0.86

0.86

 

0.86

0.87

0.88

0.89

 

0.90

0.91

Nominal Btuh

 

 

67

0.67

0.67

 

0.68

0.68

0.69

0.70

 

0.71

0.71

Models

 

 

72

0.50

0.50

 

0.51

0.51

0.51

0.52

 

0.52

0.53

 

 

 

LEGEND

DB — Dry Bulb

WB — Wet Bulb

43

Page 43
Image 43
Carrier 592-085 warranty Cooling Performance, Cooling Sensible Heat Factors SHF AT 80 F Indoor DB

592-085 specifications

The Carrier 592-085 is a leading-edge commercial air conditioning unit designed to provide efficient cooling solutions for various business environments. Known for its reliability, performance, and advanced technology, the Carrier 592-085 has become a popular choice among facility managers and HVAC professionals alike.

One of the primary features of the Carrier 592-085 is its impressive cooling capacity, which can handle large spaces with ease. The unit operates effectively in various climates, maintaining optimal indoor temperatures even during the hottest summer months. With a cooling capacity rating of 8.5 tons, it can accommodate medium to large commercial spaces, ensuring comfort for employees and customers.

The unit is equipped with advanced inverter technology, which allows it to adjust cooling output based on real-time demand. This not only enhances energy efficiency but also leads to significant cost savings over time. The inverter-driven compressor operates silently, reducing noise levels without compromising on performance.

In addition to its energy-efficient capabilities, the Carrier 592-085 features highly innovative refrigerant management. The unit uses R-410A refrigerant, which is environmentally friendly and contributes to reducing ozone depletion. This makes it an ideal choice for businesses looking to minimize their ecological footprint while maintaining effective cooling.

The Carrier 592-085 also boasts durable construction, with weather-resistant materials designed to withstand harsh external conditions. This ensures longevity and reduces maintenance needs in the long run. The unit's design also includes access panels for convenient servicing, making it easier for technicians to perform routine maintenance and repairs.

Moreover, the Carrier 592-085 is compatible with advanced building management systems, allowing for seamless integration into existing operations. Features such as remote monitoring and control provide users with the flexibility to manage their HVAC systems efficiently, enhancing overall operational efficiency.

In summary, the Carrier 592-085 stands out in the commercial air conditioning market due to its robust performance, energy efficiency, and advanced features. From its inverter technology to eco-friendly refrigerant usage and durable design, this unit provides a comprehensive solution for those seeking reliable cooling in commercial settings. It represents a smart investment for businesses that prioritize both comfort and sustainability.