Carrier 592-085 Easy Access To Chassis, Hidden Controls, Temperature Limiter and Control Knob

Models: 592-085

1 56
Download 56 pages 23.58 Kb
Page 10
Image 10
EASY ACCESS TO CHASSIS

PRODUCT FEATURES AND BENEFITS (cont)

EASY ACCESS TO CHASSIS

Access to the chassis simply requires removing four screws and then sliding the chassis out of the sleeve for service.

CHASSIS ATTACHMENT SCREWS (SAME LOCATION ON OPPOSITE SIDE)

PLUG TEST/

RESET BUTTONS

Easy Service Access

HIDDEN CONTROLS

The factory-wired control box houses all control com- ponents and is quickly accessible without removing the chassis from the wall sleeve. By simply removing two screws on control box, the hinged door lowers, providing quick access to all the electrical compo- nents. The wiring diagram is located on the front of the control box door.

Temperature Limiter and Control Knob

The limiter reduces operating costs by allowing the owner to control the range of cooling and heating tem- peratures available to the occupant. It is located under the front panel on control box, out of the occupant’s sight. Each setting on the limiter is equivalent to 5° F and the range of temperature settings available to the owner is from 60 to 90 F. The limiter is not pre-set at the factory (providing full range for the occupant).

Fan Cycle Switch

The fan cycle switch allows the fan to operate in

2 modes:

Continuous — This setting allows the fan to run continuously, circulating air even when the temper- ature setting has been satisfied. This setting, which helps to keep the room temperature closer to the thermostat setting, is used for maximum comfort.

Cycle — This setting allows the fan to cycle on and off with the compressor during heating or cooling. The fan stops when the temperature setting is reached. The longer unit off-time makes this option more energy-efficient with only slightly wider vari- ations in room temperature.

NOTE: On wall thermostat models, the fan cycle/ continuous feature is typically located at the wall thermostat.

Outdoor Air Vent Control

Control of the outdoor-air vent is handled by a vent handle located under the front panel on the left side of the unit. This handle rotates to manually open and close the outdoor vent.

The vent will provide 50 cfm of fresh air.

NOTE: If more fresh air cfm is required, a Power-Vent Kit is available (see accessories).