Analog Ports

Loop-reverse-battery signaling

Network-provided reverse-battery signaling

E&M signaling

Customer-installation-provided loop-start supervision.

8.2.1Update Interval

The Update Interval window graphically represents the user-selected interval for updating the infor- mation on this screen. Set the interval by dragging the slide control up and down with your mouse cursor. To turn off updates, put the slide control at its lowest position.

Figure 8-2: Update Intervals

The interpretation of the signaling bits for D4 framing are as follows:

D4 (SF) Framing Format

See the legend at the end of this table for explanations of abbreviations.

Signaling Type

State

 

Receive (Network-

Transmit

 

 

 

 

to-Subscriber)

(Subscriber-to-

 

 

 

 

 

Network)

 

 

 

 

 

 

 

 

 

Rx

Tx

A

B

A

B

 

 

 

 

 

 

 

Loop-start

LCF

LO (on hook)

0

1

0

1

signaling (FXO-

 

 

 

 

 

 

FXS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ringing

LC (off hook)

0

0

1

1

 

 

 

 

 

 

 

Loop-start

LCF

LO (on hook)

0

1

0

1

signaling with

 

 

 

 

 

 

RLCF (FXO-FXS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RLCF

LC (off hook)

0

1/0

1

1

LCFO

1

1

8-5

Page 59
Image 59
Carrier Access AB II manual Update Intervals