1.4 Connecting the PC Directly to the Access Bank II

The RS-232 Management cable (provided) is equipped with a male 26-pin D-type subminiature connector on the end that mates with the secondary RS-232 connector pins of the Management port, and a female 25-pin connector on the DCE end for connection to the RS-232 communications interface of the PC.

D-SUB-26 (male)

 

DCE-DB-25

SECONDARY

BRAID

(female)

 

 

 

 

 

1 SHIELD

 

1 SHIELD

 

 

7 GND

 

GND

7 GND

 

 

 

 

 

 

TXD

 

 

14 STXD

 

2 TX

 

 

 

RXD

 

 

16 SRXD

 

3 RX

 

 

 

RTS

 

 

19 SRTS

 

4 RTS

 

 

 

CTS

 

 

13 SCTS

 

5CTS

 

 

 

DTR

 

 

10 SDTR

 

20DTR

 

 

 

CD

 

 

12 SCD

 

8CD

 

 

 

 

 

 

 

 

 

 

 

 

 

RS-232 Management Port

 

 

on Access Bank II

 

 

Local PC with Remote

Monitor Software

56￿￿￿￿￿0DQDJHPHQW￿&DEOH

&RPP￿3RUW￿RQ

0DQDJHPHQW￿3&

56￿￿￿￿￿0DQDJHPHQW 3RUW￿RQ￿$FFHVV￿%DQN￿,,

To connect a local PC to the Access Bank II using the RS-232 Management Cable:

1.Set the System Configuration Local/Remote DIP switch 1 on the Access Bank II Control Panel to the Remote mode.

1-4

Page 14
Image 14
Carrier Access AB II manual 560DQDJHPHQW&DEOH, Connecting the PC Directly to the Access Bank