Operation CFL Mode

Your fan has the ability to disable the dimming feature to allow the use of

 

CFL bulbs.

 

 

 

 

 

Caution: CFL bulbs will not

To activate CFL mode:

 

 

function properly when

 

 

dimmed, which may result

1.  Turn the fan off by pressing the

 

power button.

in flickering or reduced bulb

 

 

 

 

life.

2.  Allow the fan to remain off for at least 5 seconds.

 

3.  Press the power button again to restore power to the fan.

4.  Immediately press and hold the "1" and "3" buttons for at least 5 seconds.The fans lights will go to 100% brightness and the dimming function will be disabled.

To cancel CFL mode:

5.  Turn the fan off by pressing the power button.

6.  Allow the fan to remain off for at least 5 seconds.

7.  Press the power button again to restore power to the fan.

8.  Immediately press and hold the "2" and "4" buttons for at least 5 seconds.The fans lights will dim to 50% brightness and the dimming function will be enabled. Press and hold the light buttons until the desired dimmer setting is reached.

Changing Frequency Setting

NOTE: All fans leave the factory set to “111111”

You will only have to change the dip switch settings in the remote if you are using more than one fan in the same area and want to control them separately.

DIP SWITCHES

 

DIP SWITCHES

NOTE: DO NOT set dip switch setting in the

SET TO ‘111111’

remote to ‘0000’, this may cause frequency

(Factory Setting)

interference from other Casablanca Products.

 

 

 

 

 

1.  Turn power OFF at the circuit breaker or fuse box and at the toggle switch, for the fan you want to change.

2.  Remove the screws and switch plate from the existing switch box. 3.  Remove the screws holding the switch in the switch box.

4.  Pull the existing W-74 switch from the switch box to expose the dip switches located on the side of the control as shown in Figure #1.

5.  Change the dip switch settings, assuring that they are different from the previously installed Direct-Touch fan.

6.  Mount the W-74 Wall Control unit back into the wall electrical box.

7.  At the circuit breaker or fuse box and at the toggle switch, turn the power off for the fan whose frequency you are changing.

8.  Within 20 seconds of restoring power to the ceiling fan and the W-74

Wall Control press and hold both the “1” and reverse buttons as shown in Figure #2. For 3 seconds, you will hear one tone from the Piezo Buzzer indicating the command has been accepted.The Fan and Lights will be off.

(Figure 1)

DIP SWITCHES SET TO ‘000000’

1 2

0

4 3

(Figure 2)

20