38AutoView 1415/1515/2015 Switch Installer/User Guide

NOTE: AVRIQ or IAC modules may appear to be offline while being upgraded.

Figure 3.21: Diagnostics Dialog Box

Next to each item to be tested, you will see a pass (green circle) or fail (red x) symbol display to the left of each item as that test finishes. The following table details each of the tests.

Table 3.5: Diagnostic Test Details

Test

Description

 

 

Memory Tests

Reports on the condition of the main board RAM

 

 

Firmware CRCs

Reports on the condition of the main board RAM

 

 

Comm Interfaces

Validates the current firmware images stored in the system’s Flash

 

 

Switch Controller test

Verifies the switch matrix controller is accessible and functional

 

 

Local Video

Indicates the condition of the local video monitor

 

 

On-line Targets

Indicates the total number of currently connected and powered targets

 

 

Offline Targets

Indicates the number of targets that have been connected successfully in the

past and are powered down

 

 

 

Suspect Targets

Indicates the number of targets that have been detected, but are either

unavailable for connection or have dropped packets during the ping tests

 

 

 

To run diagnostic tests:

1.If the OSCAR interface is not open, press Print Screen. The Main dialog box will appear.

2.Click Commands - Run Diagnostics. A warning message displays indicating that all users will be disconnected.

Page 50
Image 50
Casio 2015 manual To run diagnostic tests, Diagnostic Test Details Description