Using the Mixer

To initialize all mixer parameters

For details about how initial default settings are configured when you perform the following procedure, see “Parameter List” (page E-127).

1.While the mixer screen is displayed, hold down the R-13 (FUNCTION) button as you press the C-13 (MENU) button.

This displays the mixer menu screen with the 0next to “Initialize”.

2.Press the R-16 (ENTER) button.

3.In response to the “Sure?” message that appears, press the R-14 (YES) button to initialize all mixer parameters or the R-14 (NO) button to cancel.

To change the information displayed by the level meter while configuring part parameter settings

1.While the mixer screen is displayed, hold down the R-13 (FUNCTION) button as you press the C-13 (MENU) button.

This displays the mixer menu.

2.Use the R-17 (y) button to move the 0 to “Display” and then press the R-16 (ENTER) button.

3.Use the dial or R-14 (–, +) buttons to change the setting.

To select display of this

Select this setting:

information:

 

Part parameter setting values

Param

 

 

Volume level

Meter

 

 

4.After the setting is the way you want, press the R-15 (EXIT) button to exit the menu.

E-41