Gas conversion (to L.P.G. or Natural gas)
This appliance is regulated to work with the gas indicated in the gas regulation label.
If it has to work with another type of gas (L.P.G. or Natural gas), before the appliance is connected you must substitute the oven and grill burner injectors as follows:
a)REPLACEMENT OF THE OVEN BURNER INJECTOR
✓Open the oven door completely.
✓Remove the burner cover (Fig. 5).
✓Remove the burner by unscrewing the two front screws (Fig. 6). Take care not to damage the wire to the ignition electrode and the safety valve probe.
✓Unscrew the oven burner injector (Fig. 7) using a 7 mm spanner and substitute it with one (see table) of the correct size.
✓Replace all the components by fol lowing in reverse the operations explained above.
Figure 5 |
Figure 6
Figure 7
10 |