REGULATION OF THE MINIMUM FLAME

REGULATION OF THE MINIMUM FLAME

This needs to be done only for the oven burner (the grill is a fixed capacity) by acting on the thermostat.

Considering that in the minimum position the flame must have a length of about 4

mmand must remain lit even with a brusque passage from the maximum position to that of minimum.

The flame adjustment is done in the following way:

Light the oven burner by turning the knob on position Manual backgroundManual backgroundManual background .

Let the oven pre-heat for about 10 minutes, then take the knob to position Manual backgroundManual background (minimum) to operate at by-pass flow.

Remove the thermostat knob and by means of a thin screwdriver pass by the hole in the facia panel to unscrew of 3 turns the by-pass screw G (fig. 12)

Slowly tighten the by-pass screw G (fig. 12) until you get a flame of 3-4 mm long.

Turn off the burner and reassemble the knob.

After regulation (always with oven hot and the oven door closed) check the stability of the flame with a passage from the maximum to minimum position.

The grill is a fixed capacity and does not be adjusted.

N.B.: For Liquid gas (G 30/G 31) the screw G must be tightened thoroughly.