REGULATION OF THE MINIMUM FLAME
This needs to be done only for the oven burner (the grill is a fixed capacity) by acting on the thermostat.
Considering that in the minimum position the flame must have a length of about 4
mmand must remain lit even with a brusque passage from the maximum position to that of minimum.
The flame adjustment is done in the following way:
✓Light the oven burner by turning the knob on position .
✓Let the oven
✓Remove the thermostat knob and by means of a thin screwdriver pass by the hole in the facia panel to unscrew of 3 turns the
✓Slowly tighten the
✓Turn off the burner and reassemble the knob.
✓After regulation (always with oven hot and the oven door closed) check the stability of the flame with a passage from the maximum to minimum position.
The grill is a fixed capacity and does not be adjusted.
N.B.: For Liquid gas (G 30/G 31) the screw G must be tightened thoroughly.
Figure 12
G |
13 |