✓CONNECTION BY A THREE PIN SOCKET (Fig. 1)
➜The appliance must be connected to a
➜If the mains plug is unsuitable for the socket outlet in your home or is removed for any other reason, then the cut off plug should be disposed of safely to prevent the hazard of electric shock.
➜There is a danger of electric shock if the cut off plug is inserted into any 13 amp socket outlet.
✓CONNECTION USING FIXED WIRING (Fig. 2)
➜It is possible to connect the appliance directly to the mains supply by means of a heavy duty switch with 3 mm minimum distance between the contacts.
➜A double pole switch must be provided no further than 2 metres from the appli- ance to the electrical supply. All supply current and earth conductors must be able to withstand an ambient temperature of 75°C.
➜The appliance must be protected by a 3 amp fuse.
Figure 2
DOUBLE POLE SWITCHED | |
FUSED SPUR OUTLET | |
FUSE | ON |
| |
| 4 |