13/ IF OPERATING ABNORMALITIES OCCUR

• SUMMARY OF THE FAULTS

d01: water supply fault (tap)

d07: overflow / anti-leak fault

 

 

d02: draining fault

d08: sprinkling distribution fault

 

 

d03: heating fault

d11: pressure sensor fault

 

 

d04: temperature fault

d12: filling fault (water inlet detection system)

 

 

d05: fault – motor under load

d13: overheating fault

 

 

d06: fault - motor overload

d14: installation fault : (incorrect drainage

connection or inadequate flow rate and tap).

 

 

 

• BEFORE CALLING FOR SERVICE

Problem

Possible Causes

What to do?

 

 

 

The door catches when closing

- Appliance not stable

- Adjust the feet.

 

- Door not centred on the tub

- Re-centre by adjusting the

 

 

rear feet.

 

 

 

The upper basket does not stay

- Poor manipulation (the basket

- Act more progressively (see

in the high position

is being pulled upwards too

instructions), one side and

 

quickly)

then the other.

 

 

 

Small leak around or under the

- Leak from the tap.

- Check that a seal is fitted and

appliance (move the appliance

- Leak from the appliance.

retighten the nut.

to locate the leak)

- Close the water tap and call a

 

(Cf. table fault d07).

technician.

 

 

 

 

 

Small leak at the door

- Appliance not stable or not level

- Adjust the feet.

 

- Door not centred on the tub.

- Re-centre by adjusting the rear

 

 

feet.

 

 

 

31

Page 31
Image 31
CDA WF250SS manual Summary of the Faults, Before Calling for Service