Jefferson Direct Vent/Natural Vent Gas Heater
Assembly Procedures
WARNING
Failure to position the parts in accor- dance with these diagrams or failure to
use only parts specifically approved for use with this heater may result in property dam- age or personal injury.
This heater and components are heavy. Have help available for assembly.
Tools Required
• | Phillips screwdriver (stub) | • | power drill |
• | utility knife | • | reciprocating saw |
• metal drill bit: size 28 (.140”/3.5mm)
Unpack the Stove
The parts bag containing this manual also includes the following parts:
• | Remote Switch | • | Switch Bracket |
• | Switch Wire | • | |
• | Cement | • | Restrictor Plate |
• | #10 Sheet metal screws (2) |
The logset and 4” inner vent starter pipe are packed in- side the firebox. Use the following procedure to unpack these parts.
1.Lift the stove front up and then swing the bottom out and away to disengage it from the stove body. Refer to Figure 37, Page 23.
2.Swing open the swiveling latches at the top left and right corners of the glass frame. (Fig. 12)
ST208
Fig. 12 Swivel the latches to release the glass frame from the firebox.
3.Pull the top edge of the glass and frame assembly away from the firebox and lift it off its supports on the bottom of the firebox face. Place the assembly out of the way on a flat, padded surface such as a counter protected by a towel.
4.Take the logset and all other loose parts out of the firebox and set them aside in a protected area for installation after the venting is complete.
NOTE: Verify the two relief doors (located on top of the firebox) are properly seated on the gasket. The doors should sit flush on the gasket and should lift easily from the seal around the opening.
Install the Optional Fan
WARNING
This appliance is equipped with a
If you are installing the optional convection Fan Kit #2960 (FK28), continue here. If you will not install the Fan Kit, go to Page 15, Venting System Assembly.
1.The fan kit includes a blower assembly and a rheostat assembly connected by a cable. (Fig. 14) The blower assembly and the rheostat mount to the rear shroud of the stove. The assembly includes a ‘snapstat’ which automatically turns the fan ON (or OFF) above (or below) approximately 109° F (43° C). The rheostat also provides a range of fan speed settings from Off (which overrides the snapstat function) to HIGH. Unpack and inspect the blower assembly. Confirm that the fan spins freely.
2.Attach the snapstat assembly to the snapstat brack- et with two (2) sheet metal screws. (Fig. 13) Remove the
1/2” Sheet
Metal Screw
Snapstat
Snapstat Bracket
ST239
Fig. 13 Snapstat assembly and installation.
1414 | 30004177 |