Jefferson Direct Vent/Natural Vent Gas Heater

 

Use three #5

 

 

sheet metal

 

 

screws at

 

 

each joint

 

 

 

Sealant

Storm Collar

 

 

 

Upper

 

 

edge of

#7DVSKV

flange goes

(A, B, or

 

under upper

F) Roof

 

shingles

Support

 

 

Flashing

ST221

 

 

Fig. 31

Roof support and flashing.

 

up to the ceiling, then B-vent pipe must be used. Do not mix types of B-vent pipe; use components from one maker or the another. Follow the vent component maker’s instructions exactly. The heater will also accept standard or enamelled 7” (150 mm) diameter pipe, aroudn the Type B venting, for decorative purposes only. (Fig. 32)

NOTE: The restrictor plate supplied with the stove is not used for Natural Vent applications.

The Jefferson stove, when installed as a Natural vent heater, includes a vent safety switch. (Page 32, Fig. 63)

Operating the stove when it is not connected to a properly installed and maintained venting system, or tampering with or disconnecting the vent safety switch, can result in carbon monoxide (CO) poisoning and possible death.

For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z22.1.

For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.

Install the Vent Pipe

Apply a bead of sealant around bottom end of inner starter pipe (found in bag with logset) and attach to stove. Apply a bead of sealant around top of inner starter pipe and install the Z31B00 FSDHAG Draft Hood according to Draft Hood instructions. (Fig. 33)

Attach the first section of venting to the draft hood. Depending on the length of the individual venting sections and the lengths of the decorative pipe (if installed), you may need to slip the decorative pipe over the venting sections before attaching upper sections to lower ones. The sections of decorative pipe should be oriented with their seams (if any) toward the wall;

2020

 

Decorative 7”

CFM outer pipe

 

Pipe

(7FSSK) may be

 

 

 

4” B-vent

used after Draft

 

Hood up to the

 

Pipe

ceiling.

 

 

Draft Hood

 

Adapter

 

 

 

ST358

Fig. 32

Decorative 7” pipe may be fitted around the B-vent

pipe.

 

 

sections usually do not need to be fastened at each joint, other than slip sections. If the layout includes a slip section, this should be the last section of pipe visible in the room, at the ceiling. Complete the venting according to the vent maker’s instructions.

 

ST357

Fig. 33

Install draft hood adapter.

 

30004177

Page 20
Image 20
Century Jefferson manual Install the Vent Pipe