Safety Reversing Sensor | “Learn” | |
Button | ||
|
Installed
Safety Reversing
Sensor
Your garage door opener is programmed with
Diagnostic Chart
| 1 FLASH | Symptom: One or both of the Indicator lights on the safety sensors do not glow | |
| Safety reversing sensors wire | steady. | |
• Inspect sensor wires for a short (staple in wire), correct wiring polarity (black/ | ||
| open (broken or disconnected). | ||
white wires reversed), broken or disconnected wires, replace/attach as needed. | ||
OR | ||
• Disconnect all wires from back of motor unit. | ||
| ||
| 2 FLASHES | • Remove sensors from brackets and shorten sensor wires to | |
from back each of sensor. | ||
| ||
Safety reversing sensors wire | • Reattach sending eye to motor unit using shortened wires. If sending eye | |
| shorted or black/white wire | indicator light glows steadily, attach the receiving eye. | |
| reversed. | • Align sensors, if the indicator lights glow replace the wires for the sensors. If | |
| ||
| the sensor indicator lights do not light, replace the safety sensors. |
| 3 FLASHES | Symptom: LED is not lit on door control. | |
| Door control or wire | • Inspect door control/wires for a short (staple in wire), replace as needed. | |
• Disconnect wires at door control, touch wires together. If motor unit activates, | ||
| shorted. | ||
replace door control. | ||
| ||
| • If motor unit does not activate, disconnect door control wires from motor unit. | |
| Momentarily short across red and white terminals with jumper wire. If motor | |
| unit activates, replace door control wires. |
| 4 FLASHES | Symptom: Sending indicator light glows steadily, receiving indicator light is | |
| Safety reversing sensors | dim or flashing. | |
• Realign receiving eye sensor, clean lens and secure brackets. | ||
| slightly misaligned | ||
| ||
| (dim or flashing LED). | • Verify door track is firmly secured to wall and does not move. |
| 5 FLASHES | Symptom: Motor has overheated; the motor unit does not operate or trolley is | |
| Motor overheated or | stuck on stop bolt = Motor unit hums briefly; RPM Sensor = Short travel | |
| possible RPM sensor | • Unplug unit to reset. Try to operate motor unit, check diagnostic code. | |
| failure. Unplug to reset. | ||
• If it is still flashing 5 times and motor unit moves | ||
| ||
| RPM sensor. | |
| • If motor unit doesn’t operate, motor unit is overheated. Wait 30 minutes and | |
| retry. If motor unit still will not operate replace logic board. |
| 6 FLASHES | Symptom: Motor unit doesn’t operate. | |
| Motor Circuit Failure. | • Replace logic board because motor rarely fails. | |
| ||
| Replace Receiver |
| |
| Logic Board. |
| |