MOUNTING AND WIRING THE SAFETY SENSORS

Slide a 1/4"-20x1/2" carriage bolt head into the slot on each sensor. Use wing nuts to fasten sensors to brackets, with lenses pointing toward each other across the door. Be sure the lens is not obstructed by a bracket extension (Figure 5).

Finger tighten the wing nuts.

Recommended Wire Routing

1.Using insulated staples, run the wires from both sensors to the rail at the door header (Figure 6).

2.Run the wires through wire clips at the top of the rails.

NOTE: If your access door is near the garage door, you may choose to install the door control at this time and run the door control wire along the rail with the sensor wires.

Figure 6

Sensor Wire

Wire Clips

Rail

Wing Nut

Carriage Bolt 1/4"-20x1/2"

Lens

HARDWARE SHOWN ACTUAL SIZE

Carriage Bolt

Wing Nut

Staples

1/4"-20x1/2"

1/4"-20

 

Bell Wire

Safety Reversing Sensor Invisible Light Beam

 

Protection Area

Safety Reversing Sensor

 

13