Telco Line

Wiring Multiple Units to Telco Line

Up to 7 units can share the same phone line. The bypass boards allow the units to be disconnected without interrupting normal telephone operation.

NOTE: Installation where fiber optic phone lines are present may require additional modifications from your telephone provider. Contact your provider for more information.

When the units are in use, the bypass switches must be set to the operate position.

When the units are disconnected, the bypass switches must be set to the bypass position.

Bypass Board for Unit 1

Bypass Board for Unit 2

Last Bypass Board

 

OPERATE

 

BYPASS

OPERATE

 

BYPASS

BYPASS

 

Home Phone

 

 

 

 

 

 

 

Ring Tip 4

3 2

1 Ring Tip

Ring Tip 4

3 2

1 Ring Tip

Ring Tip

Telco Entrance Box

Demarcation Point

HOME

SYSTEM

TELCO

HOME

SYSTEM

TELCO

TELCO

Ring

 

Ring

 

 

Tip

Tip

 

Tip

 

Tip

 

 

Ring

Ring

 

Multiple Units to

Never run Telco wires and High Voltage wires in the same conduit. The high voltage wires may interfere with the Telco wires, possibly causing the system to malfunction.

IMPORTANT: The Bypass Boards (located inside the property) allow access to the phone in case any of the units fail.

Use 18-24 AWG 2 twisted pair

IMPORTANT: You must program the unit ID's for each unit wired in the series. See Keypad Programming Manual.

Wiring

DO NOT overload the removable terminal block connectors. One wire per hole.

 

RES

 

RES

3

Ring

1

Ring

4

Tip

2

Tip

 

TELCO

 

TELCO

1

Ring

3

Ring

2

Tip

4

Tip

Unit ID 1

Unit ID 2

Output Board

Output Board

(See page 6)

(See page 6)

Page 10